MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1442-200x.2009.02856.x

Медицинская библиотека · Pediatrics international : official journal of the Japan Pediatric Society · 2009

Reduced oxygen protocol decreases the incidence of threshold retinopathy of prematurity in infants of <33 weeks gestation.

Tokuhiro Yumiko, Yoshida Tomoko, Nakabayashi Yoshinobu, Nakauchi Shohei, Nakagawa Yumi, Kihara Minako, Mitsufuji Nobuto, Kizaki Zenro

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The relationship between oxygen and retinopathy of prematurity (ROP) has been studied frequently, and a pulse oximeter has the potential to facilitate the control of oxygen fluctuation in neonates. The objective of the present study was to compare the incidence of threshold ROP (stage 3 requiring laser treatment and stage 4) in infants of <33 weeks gestation after implementing a new clinical O(2) management practice.

METHODS

A retrospective study of data from the Kyoto First Red Cross Hospital neonatal intensive care unit (NICU) from 1 July 2004 to 31 October 2007 (closed 1 December 2006-30 March 2007 for reconstruction). A reduced oxygen protocol was implemented to maintain oxygen saturation (SpO(2)) values using a pulse oximeter between 88% and 92%. The incidence of threshold ROP in the earlier period (1 July 2004-31 December 2005) and the later period (1 January 2006-31 October 2007) were compared.

RESULTS

The incidence of threshold ROP significantly decreased from 32.2% to 16.7%, after changing to the reduced oxygen protocol (P < 0.05).

CONCLUSION

A significant decrease in the rate of threshold ROP in infants of <33 weeks gestation was observed after implementation of the new clinical O(2) management practice.

Для цитирования: Tokuhiro Yumiko, Yoshida Tomoko, Nakabayashi Yoshinobu, Nakauchi Shohei, Nakagawa Yumi, Kihara Minako, Mitsufuji Nobuto, Kizaki Zenro. Reduced oxygen protocol decreases the incidence of threshold retinopathy of prematurity in infants of <33 weeks gestation.. Pediatrics international : official journal of the Japan Pediatric Society. 2009. DOI: 10.1111/j.1442-200x.2009.02856.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.