MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiol.14132832

Медицинская библиотека · Radiology · 2014

Assessing improvement in detection of breast cancer with three-dimensional automated breast US in women with dense breast tissue: the SomoInsight Study.

Brem Rachel F, Tabár László, Duffy Stephen W, Inciardi Marc F, Guingrich Jessica A, Hashimoto Beverly E, Lander Marla R, Lapidus Robert L, Peterson Mary Kay, Rapelyea Jocelyn A, Roux Susan, Schilling Kathy J, Shah Biren A, Torrente Jessica, Wynn Ralph T, Miller Dave P

Оценочное исследованиеСтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To determine improvement in breast cancer detection by using supplemental three-dimensional (3D) automated breast (AB) ultrasonography (US) with screening mammography versus screening mammography alone in asymptomatic women with dense breasts.

MATERIALS AND

METHODS

Institutional review board approval and written informed consent were obtained for this HIPAA-compliant study. The SomoInsight Study was an observational, multicenter study conducted between 2009 and 2011. A total of 15 318 women (mean age, 53.3 years ± 10 [standard deviation]; range, 25-94 years) presenting for screening mammography alone with heterogeneously (50%-75%) or extremely (>75%) dense breasts were included, regardless of further risk characterization, and were followed up for 1 year. Participants underwent screening mammography alone followed by an AB US examination; results were interpreted sequentially. McNemar test was used to assess differences in cancer detection.

RESULTS

Breast cancer was diagnosed at screening in 112 women: 82 with screening mammography and an additional 30 with AB US. Addition of AB US to screening mammography yielded an additional 1.9 detected cancers per 1000 women screened (95% confidence interval [CI]: 1.2, 2.7; P < .001). Of cancers detected with screening mammography, 62.2% (51 of 82) were invasive versus 93.3% (28 of 30) of additional cancers detected with AB US (P = .001). Of the 82 cancers detected with either screening mammography alone or the combined read, 17 were detected with screening mammography alone. Of these, 64.7% (11 of 17) were ductal carcinoma in situ versus 6.7% (two of 30) of cancers detected with AB US alone. Sensitivity for the combined read increased by 26.7% (95% CI: 18.3%, 35.1%); the increase in the recall rate per 1000 women screened was 284.9 (95% CI: 278.0, 292.2; P < .001).

CONCLUSION

Addition of AB US to screening mammography in a generalizable cohort of women with dense breasts increased the cancer detection yield of clinically important cancers, but it also increased the number of false-positive results.

Для цитирования: Brem Rachel F, Tabár László, Duffy Stephen W, Inciardi Marc F, Guingrich Jessica A, Hashimoto Beverly E, Lander Marla R, Lapidus Robert L, Peterson Mary Kay, Rapelyea Jocelyn A, Roux Susan, Schilling Kathy J, Shah Biren A, Torrente Jessica, Wynn Ralph T, Miller Dave P. Assessing improvement in detection of breast cancer with three-dimensional automated breast US in women with dense breast tissue: the SomoInsight Study.. Radiology. 2014. DOI: 10.1148/radiol.14132832.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.