MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiol.14131502

Медицинская библиотека · Radiology · 2014

Mammographic performance in a population-based screening program: before, during, and after the transition from screen-film to full-field digital mammography.

Hofvind Solveig, Skaane Per, Elmore Joann G, Sebuødegård Sofie, Hoff Solveig Roth, Lee Christoph I

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare performance measures before, during, and after the transition from screen-film mammography (SFM) to full-field digital mammography (FFDM) in a population-based screening program.

MATERIALS AND

METHODS

No institutional review board approval was required for this analysis involving anonymized data for women aged 50-69 years enrolled in the Norwegian Breast Cancer Screening Program during 1996-2010. The χ(2) test was used to examine the equality of proportions of recall rates, positive predictive value of recall examinations and of invasive procedures, in addition to rates of screening-detected and interval cancers in women initially screened with SFM and FFDM and for women subsequently screened with SFM after SFM, FFDM after SFM, and FFDM after FFDM.

RESULTS

The recall rate was 3.4% (47 091 of 1 391 188) for SFM and 2.9% (13 130 of 446 172) for FFDM (P < .001). The biopsy rate was 1.4% (19 776 of 1 391 188) for SFM and 1.1% (5108 of 446 172) for FFDM (P < .001). The rate of screening-detected ductal carcinoma in situ was higher (P = .019) while the rate of invasive breast cancer was lower (P < .001) for FFDM compared with those for SFM. The rate of both invasive screening-detected and interval breast cancer remained stable during the transition from SFM to FFDM (when the previous examination was SFM) and after FFDM was firmly established (when the previous examination was FFDM, >25 months after FFDM adoption) (P < .05). The positive predictive value of recall examinations and of invasive procedures increased from 19.3% (4559 of 23 598) and 48.3% (4651 of 9623) to 22.7% (681 of 2995) and 57.5% (689 of 1198), respectively, after adoption of FFDM (P < .001).

CONCLUSION

After the initial transitional phase from SFM to FFDM, population-based screening with FFDM is associated with less harm because of lower recall and biopsy rates and higher positive predictive values after biopsy than screening with SFM.

Для цитирования: Hofvind Solveig, Skaane Per, Elmore Joann G, Sebuødegård Sofie, Hoff Solveig Roth, Lee Christoph I. Mammographic performance in a population-based screening program: before, during, and after the transition from screen-film to full-field digital mammography.. Radiology. 2014. DOI: 10.1148/radiol.14131502.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.