MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0284185114520860

Медицинская библиотека · Acta radiologica (Stockholm, Sweden : 1987) · 2014

Contrast-enhanced ultrasound using real-time contrast harmonic imaging in invasive breast cancer: comparison of enhancement dynamics with three different doses of contrast agent.

Saracco Ariel, Szabó Botond K, Aspelin Peter, Leifland Karin, Tánczos Ervin, Wilczek Brigitte, Axelsson Rimma

Сравнительное исследованиеКонтролируемое клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In the last few years new potential applications have been developed for contrast-enhanced ultrasound (CEUS) and the management of breast diseases, but there is still some debate concerning the optimal dose to evaluate breast lesions, especially as a diagnostic tool.

PURPOSE: To compare different CEUS doses of injected contrast agent in order to establish an optimal dose for the diagnosis of invasive breast cancer.

MATERIAL AND

METHODS

In Group A we compared the bolus dose of 1.2 mL vs. 2.4 mL and in Group B we compared the bolus dose of 2.4 mL vs. 4.8 mL (26 and 25 invasive carcinomas, respectively). CEUS was performed in real-time contrast harmonic imaging (CHI) using a L9-3 MHz probe. All examinations were recorded in a contrast side/side imaging mode loop for 120 s. Wash-in and wash-out patterns of the contrast agent were analyzed with advanced US quantification software and kinetic curves were used for statistical analysis.

RESULTS

In Group B (2.4 mL vs. 4.8 mL), more and stronger correlation was found among kinetic parameters (area under the curve, P < 0.00001; lognormal model parameters, μ, P = 0.0007 and σ, P < 0.0001; mean transit time, P < 0.0001; model-based wash-out ratios, W21m, P = 0.0002; W50m, P = 0.0001; time-to-peak, P = 0.005) as compared to Group A (1.2 mL vs. 2.4 mL).

CONCLUSION

The optimal way to evaluate kinetic features of invasive breast tumors using real-time CEUS is with an injection of contrast agent of either 2.4 mL or 4.8 mL.

Для цитирования: Saracco Ariel, Szabó Botond K, Aspelin Peter, Leifland Karin, Tánczos Ervin, Wilczek Brigitte, Axelsson Rimma. Contrast-enhanced ultrasound using real-time contrast harmonic imaging in invasive breast cancer: comparison of enhancement dynamics with three different doses of contrast agent.. Acta radiologica (Stockholm, Sweden : 1987). 2014. DOI: 10.1177/0284185114520860.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.