MedElevator Войти в исследования
← Поиск публикаций

DOI 10.47102/annals-acadmedsg.2020564

Медицинская библиотека · Annals of the Academy of Medicine, Singapore · 2021

Predictors and outcomes of high-flow nasal cannula failure following extubation: A multicentre observational study.

Kansal Amit, Dhanvijay Shekhar, Li Andrew, Phua Jason, Cove Matthew Edward, Ong Wei Jun Dan, Puah Ser Hon, Ng Vicky, Tan Qiao Li, Manalansan Julipie Sumampong, Zamora Michael Sharey Nocon, Vidanes Michael Camba, Sahagun Juliet Tolentino, Taculod Juvel, Tan Addy Yong Hui, Tay Chee Kiang, Chia Yew Woon, Sewa Duu Wen, Chew Meiying, Lew Sennen J W, Goh Shirley, Tan Jonathan Jit Ern, Ramanathan Kollengode, Mukhopadhyay Amartya, See Kay Choong

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

Despite adhering to criteria for extubation, up to 20% of intensive care patients require re-intubation, even with use of post-extubation high-flow nasal cannula (HFNC). This study aims to identify independent predictors and outcomes of extubation failure in patients who failed post-extubation HFNC.

METHODS

We conducted a multicentre observational study involving 9 adult intensive care units (ICUs) across 5 public hospitals in Singapore. We included patients extubated to HFNC following spontaneous breathing trials. We compared patients who were successfully weaned off HFNC with those who failed HFNC (defined as re-intubation ≤7 days following extubation). Generalised additive logistic regression analysis was used to identify independent risk factors for failed HFNC.

RESULTS

Among 244 patients (mean age: 63.92±15.51 years, 65.2% male, median APACHE II score 23.55±7.35), 41 (16.8%) failed HFNC; hypoxia, hypercapnia and excessive secretions were primary reasons. Stroke was an independent predictor of HFNC failure (odds ratio 2.48, 95% confidence interval 1.83-3.37). Failed HFNC, as compared to successful HFNC, was associated with increased median ICU length of stay (14 versus 7 days, P<0.001), ICU mortality (14.6% versus 2.0%, P<0.001) and hospital mortality (29.3% versus 12.3%, P=0.006).

CONCLUSION

Post-extubation HFNC failure, especially in patients with stroke as a comorbidity, remains a clinical challenge and predicts poorer clinical outcomes. Our observational study highlights the need for future prospective trials to better identify patients at high risk of post-extubation HFNC failure.

Для цитирования: Kansal Amit, Dhanvijay Shekhar, Li Andrew, Phua Jason, Cove Matthew Edward, Ong Wei Jun Dan, Puah Ser Hon, Ng Vicky, Tan Qiao Li, Manalansan Julipie Sumampong, Zamora Michael Sharey Nocon, Vidanes Michael Camba, Sahagun Juliet Tolentino, Taculod Juvel, Tan Addy Yong Hui, Tay Chee Kiang, Chia Yew Woon, Sewa Duu Wen, Chew Meiying, Lew Sennen J W, Goh Shirley, Tan Jonathan Jit Ern, Ramanathan Kollengode, Mukhopadhyay Amartya, See Kay Choong. Predictors and outcomes of high-flow nasal cannula failure following extubation: A multicentre observational study.. Annals of the Academy of Medicine, Singapore. 2021. DOI: 10.47102/annals-acadmedsg.2020564.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.