MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-008-0969-2

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2008

Choroidal expansion during the water drinking test.

De Moraes Carlos Gustavo Vasconcelos, Reis Alexandre Soares Castro, Cavalcante Adhele Furlani de Sá, Sano Milena Eimi, Susanna Remo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the correlation between intraocular pressure (IOP) rise, ocular pulse amplitude (OPA), and choroidal thickness (ChT) during the water drinking test (WDT).

METHODS

Primary open-angle glaucoma (POAG) patients were submitted to the WDT followed by serial IOP measurements using dynamic contour tonometry (DCT), Goldman tonometry (GAT), and ChT measurements using ultrasonographic A and B-scan (USG). A control group not submitted to the test was also evaluated using DCT, GAT, and USG. Intraclass correlation coefficient (ICC) was calculated in the control group in order to assess the reproducibility of measurements. Spearman's coefficient (rho) was used to assess the correlation between the variables.

RESULTS

Thirty eyes were included in the study. There was a significant IOP rise during the WDT using both GAT and DCT (p < 0.001). The OPA and ChT measurements also increased significantly (p < 0.001). Spearman's correlation between the OPA values and ChT measurements was significant and moderate (rho = 0.40, p = 0.005). The average increase of OPA and ChT measurements occurred 15 min before the IOP rise.

CONCLUSIONS

There was a significant increase of OPA and ChT measurements followed by an IOP rise during the WDT. Increased choroidal volume due to hemodynamic forces may be enrolled in the mechanism of IOP elevation during this stress test.

Для цитирования: De Moraes Carlos Gustavo Vasconcelos, Reis Alexandre Soares Castro, Cavalcante Adhele Furlani de Sá, Sano Milena Eimi, Susanna Remo. Choroidal expansion during the water drinking test.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2008. DOI: 10.1007/s00417-008-0969-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.