MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ijg.0b013e31814b9817

Медицинская библиотека · Journal of glaucoma · 2008

Retinal nerve fiber layer thickness in normal, ocular hypertensive, and glaucomatous Indian eyes: an optical coherence tomography study.

Gyatsho Jamyang, Kaushik Sushmita, Gupta Amod, Pandav Surinder Singh, Ram Jagat

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine retinal nerve fiber layer (RNFL) thickness measurements in normal, ocular hypertensive (OHT), and glaucomatous Asian Indian eyes.

METHODS

This prospective observational cross-sectional study included patients with OHT, primary open angle glaucoma (POAG), and age-matched normal controls. The global and 4-quadrant average RNFL thickness was measured using the Stratus OCT. The main outcome measures were differences in RNFL thickness measurements between the 3 groups. The discriminating power of each parameter was evaluated by calculating areas under receiver operating characteristic curves (AROCs).

RESULTS

Twenty-three eyes of 23 POAG patients, 24 eyes of 24 OHT, and 48 eyes of 48 normal controls were analyzed. The superior, inferior, and global RNFL measurements were significantly thinner in OHTs compared with normals (P=0.031, 0.019, and 0.022, respectively). All 5 RNFL parameters were significantly thinner in the POAG group compared with OHT group (P<0.001). Parameters with largest AROCs for distinguishing glaucoma from OHT were average and inferior average RNFL measurements (0.989 and 0.979, respectively). Inferior and superior RNFL measurements had largest AROCs (0.717 and 0.700, respectively) to distinguish OHT from normal eyes.

CONCLUSIONS

Stratus OCT detected significant quantitative differences in RNFL thickness between normal, OHT, and glaucomatous Asian Indian eyes.

Для цитирования: Gyatsho Jamyang, Kaushik Sushmita, Gupta Amod, Pandav Surinder Singh, Ram Jagat. Retinal nerve fiber layer thickness in normal, ocular hypertensive, and glaucomatous Indian eyes: an optical coherence tomography study.. Journal of glaucoma. 2008. DOI: 10.1097/ijg.0b013e31814b9817.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.