MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.knee.2020.08.008

Медицинская библиотека · The Knee · 2020

Pitfalls in assessing limb alignment affected by rotation and flexion of the knee after total knee arthroplasty: Analysis using sagittal and coronal whole-body EOS radiography.

Yoo Hyun Jin, Kim Ji Eui, Kim Sung Chan, Kim Joo Sung, Yang Hee Jin, Kim Tae Woo, Lee Yong Seuk

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Inappropriate posture during radiographic assessment may lead to misunderstanding of postoperative alignment after total knee arthroplasty (TKA). The EOS system assesses coronal and sagittal alignment simultaneously. This study aimed to evaluate the effect of flexion and/or rotation on alignment, and identify the patterns of knee posture with serial follow-up using the EOS system.

METHODS

One-hundred and fifteen patients of TKA and serial whole-body EOS were included. The hip-knee-ankle (HKA) angle in the coronal and sagittal planes, femoral component rotation ratio (FCR), tibial component rotation ratio (TCR), and fibular overlap ratio (FO) were measured immediately and at six months and one year postoperatively. Total and partial correlation, using flexion and rotation as a control variable was performed.

RESULTS

The mean HKA values and flexion immediately post-operation were different compared with the values noted at six months and one year postoperatively (for all, P < 0.05). The FCR and FO were correlated with the HKA angle during all periods (for both, P < 0.05). The Pearson correlation coefficients of the HKA angle with rotation parameters decreased when flexion was controlled.

CONCLUSIONS

Combined rotation and flexion of the knee joint has a greater effect on coronal alignment compared with isolated flexion or rotation and was more frequently observed during the early postoperative period. Therefore, surgeons should be made aware of the potential knee rotation and flexion errors after TKA.

Для цитирования: Yoo Hyun Jin, Kim Ji Eui, Kim Sung Chan, Kim Joo Sung, Yang Hee Jin, Kim Tae Woo, Lee Yong Seuk. Pitfalls in assessing limb alignment affected by rotation and flexion of the knee after total knee arthroplasty: Analysis using sagittal and coronal whole-body EOS radiography.. The Knee. 2020. DOI: 10.1016/j.knee.2020.08.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.