MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2020.108837

Медицинская библиотека · European journal of radiology · 2020

Convolutional neural network-automated hepatobiliary phase adequacy evaluation may optimize examination time.

Cunha Guilherme Moura, Hasenstab Kyle A, Higaki Atsushi, Wang Kang, Delgado Timo, Brunsing Ryan L, Schlein Alexandra, Schwartzman Armin, Hsiao Albert, Sirlin Claude B, Fowler Katie J

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To develop and evaluate the performance of a fully-automated convolutional neural network (CNN)-based algorithm to evaluate hepatobiliary phase (HBP) adequacy of gadoxetate disodium (EOB)-enhanced MRI. Secondarily, we explored the potential of the proposed CNN algorithm to reduce examination length by applying it to EOB-MRI examinations.

METHODS

We retrospectively identified EOB-enhanced MRI-HBP series from examinations performed 2011-2018 (internal and external datasets). Our algorithm, comprising a liver segmentation and classification CNN, produces an adequacy score. Two abdominal radiologists independently classified series as adequate or suboptimal. The consensus determination of HBP adequacy was used as ground truth for CNN model training and validation. Reader agreement was evaluated with Cohen's kappa. Performance of the algorithm was assessed by receiver operating characteristics (ROC) analysis and computation of the area under the ROC curve (AUC). Potential examination duration reduction was evaluated descriptively.

RESULTS

1408 HBP series from 484 patients were included. Reader kappa agreement was 0.67 (internal dataset) and 0.80 (external dataset). AUCs were 0.97 (0.96-0.99) for internal and 0.95 (0.92-96) for external and were not significantly different from each other (p = 0.24). 48 % (50/105) examinations could have been shorter by applying the algorithm.

CONCLUSION

A proposed CNN-based algorithm achieves higher than 95 % AUC for classifying HBP images as adequate versus suboptimal. The application of this algorithm could potentially shorten examination time and aid radiologists in recognizing technically suboptimal images, avoiding diagnostic pitfalls.

Для цитирования: Cunha Guilherme Moura, Hasenstab Kyle A, Higaki Atsushi, Wang Kang, Delgado Timo, Brunsing Ryan L, Schlein Alexandra, Schwartzman Armin, Hsiao Albert, Sirlin Claude B, Fowler Katie J. Convolutional neural network-automated hepatobiliary phase adequacy evaluation may optimize examination time.. European journal of radiology. 2020. DOI: 10.1016/j.ejrad.2020.108837.