Modelling eye lengths and refractions in the periphery.

Ramamirtham Ramkumar, Akula James D, Curran Amber-Lee K, Szczygiel Justyna, Lancos Annie M, Grytz Rafael, Ferguson R Daniel, Fulton Anne B

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: To create a simplified model of the eye by which we can specify a key optical characteristic of the crystalline lens, namely its power.

METHODS

Cycloplegic refraction and axial length were obtained in 60 eyes of 30 healthy subjects at eccentricities spanning 40° nasal to 40° temporal and were fitted with a three-dimensional parabolic model. Keratometric values and geometric distances to the cornea, lens and retina from 45 eyes supplied a numerical ray tracing model. Posterior lens curvature (PLC) was found by optimising the refractive data using a fixed lens equivalent refractive index ( n eq ). Then, n eq was found using a fixed PLC.

RESULTS

Eccentric refractive errors were relatively hyperopic in eyes with central refractions ≤-1.44 D but relatively myopic in emmetropes and hyperopes. Posterior lens power, which cannot be measured directly, was derived from the optimised model lens. There was a weak, negative association between derived PLC and central spherical equivalent refraction. Regardless of refractive error, the posterior retinal curvature remained fixed.

CONCLUSIONS

By combining both on- and off-axis refractions and eye length measurements, this simplified model enabled the specification of posterior lens power and captured off-axis lenticular characteristics. The broad distribution in off-axis lens power represents a notable contrast to the relative stability of retinal curvature.

Для цитирования: Ramamirtham Ramkumar, Akula James D, Curran Amber-Lee K, Szczygiel Justyna, Lancos Annie M, Grytz Rafael, Ferguson R Daniel, Fulton Anne B. Modelling eye lengths and refractions in the periphery.. Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists). 2023. DOI: 10.1111/opo.13133.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.