Three-Dimensional Quantitative Description of the Implantable Collamer Lens in the Ocular Anterior Segment of Patients With Myopia.

Zhang Tong, Huang Fanfan, Gao Ning, Du Miaomiao, Cheng Hong, Huang Wanyao, Ji Yan, Zheng Shijie, Wan Wenjuan, Hu Ke

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To describe the 3-dimensional (3D) location of the implantable collamer lens (ICL) quantitatively in the posterior ocular chamber of patients with myopia.

DESIGN

Cross-sectional study.

METHODS

To obtain visualization models before and after mydriasis, an automatic 3D imaging method based on swept-source optical coherence tomography was created. Parameters like the ICL lens volume (ILV), the tilt of the ICL and crystalline lens, the vault distribution index, and topographic maps were evaluated to describe the ICL location. Using a paired sample t test and the Wilcoxon signed rank test, the difference between nonmydriasis and postmydriasis conditions was compared.

RESULTS

The study investigated 32 eyes from 20 patients. The 3D central vault did not differ significantly before (P = .994) or after mydriasis (P = .549) compared with the 2D central vault. After mydriasis, the 5-mm ILV decreased by 0.85 mm2 (P = .016), and the vault distribution index increased significantly (P = .001). The ICL and the crystalline lens exhibited tilt (nonmydriasis: ICL total tilt 3.78 ± 1.85 degrees, lens total tilt 4.03 ± 1.53 degrees; postmydriasis: ICL total tilt 3.84 ± 1.56 degrees, lens total tilt 4.09 ± 1.64 degrees). The phenomenon of asynchronous tilt of the ICL and lens was found in 5 eyes, leading to the spatially asymmetric distribution of the ICL-lens distance.

CONCLUSION

The 3D imaging technique provided exhaustive and reliable data for the anterior segment. The visualization models offered multiple perspectives on the ICL in the posterior chamber. Before and after mydriasis, the intraocular ICL position was described by the 3D parameters.

Для цитирования: Zhang Tong, Huang Fanfan, Gao Ning, Du Miaomiao, Cheng Hong, Huang Wanyao, Ji Yan, Zheng Shijie, Wan Wenjuan, Hu Ke. Three-Dimensional Quantitative Description of the Implantable Collamer Lens in the Ocular Anterior Segment of Patients With Myopia.. American journal of ophthalmology. 2023. DOI: 10.1016/j.ajo.2023.03.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.