MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/life13020447

Медицинская библиотека · Life (Basel, Switzerland) · 2023

Key Factors in Early Diagnosis of Myopia Progression within Ocular Biometric Parameters by Scheimpflug Technology.

López-Muñoz Alfredo, Gargallo-Martínez Beatriz, Sánchez-González María Carmen, Capote-Puente Raúl, De-Hita-Cantalejo Concepción, Romero-Luna Marta, Conejero-Domínguez Juan-José, Sánchez-González José-María

СтатьяПеревод пока не подготовлен

Аннотация

The aim of this study was to evaluate the relationship between myopia and ocular biometric variables using the Pentacam AXL® single rotation Scheimpflug camera. This prospective, cross-sectional, single-center study was performed in fifty Caucasian patients aged between 18 and 30 years (24.84 ± 3.04 years). The measured variables included maximum and minimum keratometry (K1 and K2, respectively), anterior chamber depth (ACD), corneal horizontal diameter or white to white (WTW), central corneal thickness (CCT), corneal asphericity (Q), and axial length (AXL). The tomographic and biometric measurements were considered optimal when the quality factor was greater than 95% according to the manufacturer's software instructions. The AXL presented a significant correlation with the spherical equivalent without cycloplegia (SE without CP), age at onset of myopia (r = -0.365, p = 0.012), mean keratometry (Km) (r = -0.339, p = 0.016), ACD (r = 0.304, p = 0.032), and WTW (r = 0.406, p = 0.005). The eyes with AXL higher than 25 mm had earlier onset; higher SE without CP, AXL, and Q; and a flatter Km. AXL is the biometric variable with the greatest influence on the final refractive state in the adult myopic eye. Ophthalmologists and optometric management must consider these biometric differences in order to identify the most appropriate correction techniques in each case. The use of the Pentacam AXL in ocular biometric measurement is effective, reproducible, and non-invasive.

Для цитирования: López-Muñoz Alfredo, Gargallo-Martínez Beatriz, Sánchez-González María Carmen, Capote-Puente Raúl, De-Hita-Cantalejo Concepción, Romero-Luna Marta, Conejero-Domínguez Juan-José, Sánchez-González José-María. Key Factors in Early Diagnosis of Myopia Progression within Ocular Biometric Parameters by Scheimpflug Technology.. Life (Basel, Switzerland). 2023. DOI: 10.3390/life13020447.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.