MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001171

Медицинская библиотека · Journal of cataract and refractive surgery · 2023

Prediction model of the horizontal trabecular iris angle after phakic posterior chamber implantable intraocular lens surgery.

Sánchez-Trancón Angel, Manito Santiago Cerpa, Sierra Oscar Torrado, Baptista António Manuel, Serra Pedro Miguel

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the predictors of the postoperative horizontal trabecular iris angle (TIA 750 ) after phakic posterior chamber implantable intraocular lens (IOL) surgery.

SETTING

Ophthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain.

DESIGN

Retrospective case series.

METHODS

330 eyes implanted with spherical/toric implantable collamer lens (ICL) were included in this study. From 230 eyes implanted with 13.2 mm ICL, these were divided in modeling (n = 180) and evaluation group (n = 50). Two groups implanted with 12.6 mm and 13.7 mm (n = 50 each) were also used as evaluation. Anterior-segment optical coherence tomography was used preoperatively to perform anterior chamber biometry (angle-to-angle [ATA] distance, crystalline lens rise, anterior chamber depth [ACD], cornea sagittal depth, pupil diameter, nasal/temporal TIA 750 ); postoperatively for measuring the vault, pupil diameter and nasal/temporal TIA 750 . Corneal curvature and horizontal visible iris diameter were measured using optical tomography. Bivariate correlation analysis was used to determine associations between preoperative and postoperative horizontal TIA 750 with anterior chamber biometry, ICL-related parameters and age. Finally, a multivariate linear regression model was constructed for predicting the postoperative TIA 750 .

RESULTS

Horizontal TIA 750 reduced from 42.9 ± 8.0 degrees preoperatively to 24.4 ± 5.6 degrees postoperatively. Postoperative TIA 750 was positively correlated with the preoperative TIA 750 , cornea sagittal depth and ACD, and negatively associated with the vault. The main predictors of the postoperative TIA 750 were the preoperative parameters, TIA 750 , ICLsize - ATA and pupil diameter (adjusted- R2 = 0.39). The limits of agreement between predicted and real TIA 750 were close to ±10 degrees.

CONCLUSIONS

Implantation of a phakic posterior chamber implantable IOL leads to a reduction in TIA 750 and the main factors contributing for this are the preoperative TIA 750 aperture and the vault.

Для цитирования: Sánchez-Trancón Angel, Manito Santiago Cerpa, Sierra Oscar Torrado, Baptista António Manuel, Serra Pedro Miguel. Prediction model of the horizontal trabecular iris angle after phakic posterior chamber implantable intraocular lens surgery.. Journal of cataract and refractive surgery. 2023. DOI: 10.1097/j.jcrs.0000000000001171.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.