MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.30791

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2023

Ten-year clinical outcomes from a randomized trial comparing new-generation everolimus-eluting stent versus first-generation Sirolimus-eluting stent: Results from the RESET extended study.

Shiomi Hiroki, Kozuma Ken, Morimoto Takeshi, Kadota Kazushige, Tanabe Kengo, Morino Yoshihiro, Tamura Toshihiro, Abe Mitsuru, Suwa Satoru, Ito Yoshiaki, Kobayashi Masakazu, Dai Kazuoki, Nakao Koichi, Tarutani Yasuhiro, Taniguchi Ryoji, Nishikawa Hideo, Yamamoto Yoshito, Yamasaki Tomohiro, Okamura Atsunori, Nakagawa Yoshihisa, Ando Kenji, Kobayashi Koichi, Kawai Kazuya, Hibi Kiyoshi, Kimura Takeshi, RESET Investigators

СтатьяРандомизированное исследованиеМногоцентровое исследованиеСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

New-generation drug-eluting stents (DES) achieved technological innovations and reported clinical advantages as compared with first-generation DES in clinical trials with 3-5 years follow-up. However, detailed clinical outcome data in very long-term follow-up is still scarce.

OBJECTIVES

To evaluate 10-year clinical outcomes after first- and new-generation DES implantation.

METHODS

In this extende follow-up study of the RESET, which is a largest randomized trial comparing everolimus-eluting stent (EES) with Sirolimus-eluting stent (SES), the study population consisted of 2892 patients from 84 centers. The primary efficacy and safety endpoints were target lesion revascularization (TLR) and a composite of death or myocardial infarction (MI), respectively. Complete 10-year follow-up was achieved in 87.9% of patients.

RESULTS

Cumulative 10-year incidences of TLR and non-TLR were not significantly different between EES and SES (13.9% vs. 15.7%, Log-rank p = 0.20, and 33.4% vs. 31.3%, Log-rank p = 0.30). The cumulative 10-year incidence of death/MI was also not significantly different between the groups (32.5% vs. 34.4%, Log-rank p = 0.18). Cumulative 10-year incidence of definite stent thrombosis was numerically lower in EES than in SES (1.0% vs. 1.7%, Log-rank p = 0.16). The lower risk of EES relative to SES was significant for a composite endpoint of target lesion failure (TLF: 19.6% vs. 24.9%, Log-rank p = 0.001) and target vessel failure (TVF: 26.7% vs. 31.4%, Log-rank p = 0.006).

CONCLUSION

During 10-year of follow-up, the risks for primary efficacy and safety endpoints were not significantly different between new-generation EES and first-generation SES, although EES compared with SES was associated with a lower risk for composite endpoints such as TLF and TVF.

Для цитирования: Shiomi Hiroki, Kozuma Ken, Morimoto Takeshi, Kadota Kazushige, Tanabe Kengo, Morino Yoshihiro, Tamura Toshihiro, Abe Mitsuru, Suwa Satoru, Ito Yoshiaki, Kobayashi Masakazu, Dai Kazuoki, Nakao Koichi, Tarutani Yasuhiro, Taniguchi Ryoji, Nishikawa Hideo, Yamamoto Yoshito, Yamasaki Tomohiro, Okamura Atsunori, Nakagawa Yoshihisa, Ando Kenji, Kobayashi Koichi, Kawai Kazuya, Hibi Kiyoshi, Kimura Takeshi, RESET Investigators. Ten-year clinical outcomes from a randomized trial comparing new-generation everolimus-eluting stent versus first-generation Sirolimus-eluting stent: Results from the RESET extended study.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2023. DOI: 10.1002/ccd.30791.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.