MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-022-15616-6

Медицинская библиотека · Scientific reports · 2022

Performance evaluation of a non-invasive one-step multiplex RT-qPCR assay for detection of SARS-CoV-2 direct from saliva.

Jenkins Harry H, Lopez Ana A Tellechea, Tarantini Francesco Saverio, Tomlin Hannah, Scales Danielle, Lee I-Ning, Wu Siyu, Hyde Ralph, Lis-Slimak Katarzyna, Byaruhanga Timothy, Thompson Jamie L, Pijuan-Galito Sara, Doolan Lara, Kaneko Kazuyo, Gwynne Penny, Reffin Caroline, Park Emily, Dey Jayasree, Hill Jack, Arendt-Tranholm Asta, Stroud Amy, Petrie Moira, Denning Chris, Benest Andrew V, Seedhouse Claire

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Polymerase chain reaction (PCR) has proven to be the gold-standard for SARS-CoV-2 detection in clinical settings. The most common approaches rely on nasopharyngeal specimens obtained from swabs, followed by RNA extraction, reverse transcription and quantitative PCR. Although swab-based PCR is sensitive, swabbing is invasive and unpleasant to administer, reducing patient compliance for regular testing and resulting in an increased risk of improper sampling. To overcome these obstacles, we developed a non-invasive one-step RT-qPCR assay performed directly on saliva specimens. The University of Nottingham Asymptomatic Testing Service protocol simplifies sample collection and bypasses the need for RNA extraction, or additives, thus helping to encourage more regular testing and reducing processing time and costs. We have evaluated the assay against the performance criteria specified by the UK regulatory bodies and attained accreditation (BS EN ISO/IEC 17,025:2017) for SARS-CoV-2 diagnostic testing by the United Kingdom Accreditation Service. We observed a sensitivity of 1 viral copy per microlitre of saliva, and demonstrated a concordance of > 99.4% between our results and those of other accredited testing facilities. We concluded that saliva is a stable medium that allows for a highly precise, repeatable, and robust testing method.

Для цитирования: Jenkins Harry H, Lopez Ana A Tellechea, Tarantini Francesco Saverio, Tomlin Hannah, Scales Danielle, Lee I-Ning, Wu Siyu, Hyde Ralph, Lis-Slimak Katarzyna, Byaruhanga Timothy, Thompson Jamie L, Pijuan-Galito Sara, Doolan Lara, Kaneko Kazuyo, Gwynne Penny, Reffin Caroline, Park Emily, Dey Jayasree, Hill Jack, Arendt-Tranholm Asta, Stroud Amy, Petrie Moira, Denning Chris, Benest Andrew V, Seedhouse Claire. Performance evaluation of a non-invasive one-step multiplex RT-qPCR assay for detection of SARS-CoV-2 direct from saliva.. Scientific reports. 2022. DOI: 10.1038/s41598-022-15616-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.