BACKGROUND

Haemorrhage from ruptured oesophageal varices is a common cause of death in people with cirrhosis. Guidelines recommend screening for varices at time of cirrhosis diagnosis and throughout the course of the disease. Conventional gastroscopy is the criterion standard for variceal screening; however, is invasive, costly, and carries risks related to use of sedation. Ultra-thin gastroscopy (using endoscopes with a shaft diameter ≤6 mm) has been proposed as an alternative method of variceal screening that mitigates these risks.

AIM: To determine the diagnostic accuracy of ultra-thin gastroscopy compared to conventional gastroscopy for the diagnosis of varices in people with cirrhosis.

METHODS

MEDLINE, EMBASE and Cochrane library databases were searched for studies that evaluated the accuracy of ultra-thin gastroscopy compared to conventional gastroscopy in the diagnosis of oesophageal varices.

RESULTS

Ten studies, 7 in known cirrhosis, with 752 participants were included in this systematic review. The overall prevalence of oesophageal varices was 42%. On bivariate modelling, pooled estimates of sensitivity and specificity were 98% (95% CI 93%-99%) and 96% (95% CI 91%-99%) respectively. The positive and negative likelihood ratios were 28 (95% CI 10.7-73.2) and 0.02 (95% CI 0.01-0.72) respectively. Kappa coefficient for inter-observer agreement for any varices ranged from 0.45 to 0.90. No serious adverse events related to ultra-thin gastroscopy were reported.

CONCLUSIONS

Ultra-thin gastroscopy is accurate in the diagnosis of oesophageal varices, safe and well tolerated. It is a valid alternative to conventional gastroscopy for the screening and surveillance of varices in people with cirrhosis.

Для цитирования: Wickremeratne Tehara, Turner Stephanie, O'Beirne James. Systematic review with meta-analysis: ultra-thin gastroscopy compared to conventional gastroscopy for the diagnosis of oesophageal varices in people with cirrhosis.. Alimentary pharmacology & therapeutics. 2019. DOI: 10.1111/apt.15282.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.