Ophthalmology · 2013
Effect of centration and circularity of manual capsulorrhexis on cataract surgery refractive outcomes.
СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Okada Mali, Hersh Dov, Paul Eldho, van der Straaten David
Аннотация
PURPOSE: To determine if postoperative refractive outcome in cataract surgery relates to centration or circularity of the capsulorrhexis.
DESIGN: Prospective, observational study.
PARTICIPANTS: One hundred thirteen eyes from 108 patients undergoing routine phacoemulsification cataract surgery with manual continuous curvilinear capsulorrhexis.
METHODS: Patients underwent refraction, and digital retroillumination photographs were obtained 1 month and 1 year after surgery. Capsulorrhexis parameters were analyzed using computer photographic software.
MAIN OUTCOME MEASURES: Postoperative spherical equivalent (SE), deviation from predicted refraction, and postoperative spectacle cylinder.
RESULTS: At 1 month, mean capsulorrhexis circularity index was 0.83 ± 0.01 mm and mean decentration was 0.30 ± 0.14 mm. There was no significant correlation between either circularity or decentration and any of the refractive outcomes of SE, deviation from predicted refraction, or spectacle cylinder at 1 month or at 1 year. In contrast, an association between capsulorrhexis decentration and change in postoperative SE from 1 month to 1 year was observed: 56% of patients with more than 0.4 mm of decentration had a change in SE of more than 0.25 diopter (D) compared with 30% with 0.4 mm or less of decentration (P = 0.04). In eyes with incomplete capsulorrhexis-optic overlap, 60% had a change in spectacle cylinder of more than 0.50 D from 1 month to 1 year, compared with 15% of eyes with complete overlap (P = 0.004).
CONCLUSIONS: Postoperative refraction at 1 year was not related to centration or circularity of the capsulorrhexis. However, decentration by more than 0.4 mm was associated with a 0.25-D change in SE and incomplete capsulorrhexis-optic overlap was associated with a 0.50-D change in spectacle cylinder from 1 month to 1 year.
DESIGN: Prospective, observational study.
PARTICIPANTS: One hundred thirteen eyes from 108 patients undergoing routine phacoemulsification cataract surgery with manual continuous curvilinear capsulorrhexis.
METHODS: Patients underwent refraction, and digital retroillumination photographs were obtained 1 month and 1 year after surgery. Capsulorrhexis parameters were analyzed using computer photographic software.
MAIN OUTCOME MEASURES: Postoperative spherical equivalent (SE), deviation from predicted refraction, and postoperative spectacle cylinder.
RESULTS: At 1 month, mean capsulorrhexis circularity index was 0.83 ± 0.01 mm and mean decentration was 0.30 ± 0.14 mm. There was no significant correlation between either circularity or decentration and any of the refractive outcomes of SE, deviation from predicted refraction, or spectacle cylinder at 1 month or at 1 year. In contrast, an association between capsulorrhexis decentration and change in postoperative SE from 1 month to 1 year was observed: 56% of patients with more than 0.4 mm of decentration had a change in SE of more than 0.25 diopter (D) compared with 30% with 0.4 mm or less of decentration (P = 0.04). In eyes with incomplete capsulorrhexis-optic overlap, 60% had a change in spectacle cylinder of more than 0.50 D from 1 month to 1 year, compared with 15% of eyes with complete overlap (P = 0.004).
CONCLUSIONS: Postoperative refraction at 1 year was not related to centration or circularity of the capsulorrhexis. However, decentration by more than 0.4 mm was associated with a 0.25-D change in SE and incomplete capsulorrhexis-optic overlap was associated with a 0.50-D change in spectacle cylinder from 1 month to 1 year.