MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/s0004-27492013000500003

Медицинская библиотека · Arquivos brasileiros de oftalmologia · 2013

Longitudinal measurements of luminance and chromatic contrast sensitivity: comparison between wavefront-guided LASIK and contralateral PRK for myopia.

Barboni Mirella Telles Salgueiro, Feitosa-Santana Claudia, Barreto Junior Jackson, Lago Marcos, Bechara Samir Jacob, Alves Milton Ruiz, Ventura Dora Fix

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: The present study aimed to compare the postoperative contrast sensitivity functions between wavefront-guided LASIK eyes and their contralateral wavefront-guided PRK eyes.

METHODS

The participants were 11 healthy subjects (mean age=32.4 ± 6.2 years) who had myopic astigmatism. The spatial contrast sensitivity functions were measured before and three times after the surgery. Psycho and a Cambridge graphic board (VSG 2/4) were used to measure luminance, red-green, and blue-yellow spatial contrast sensitivity functions (from 0.85 to 13.1 cycles/degree). Longitudinal analysis and comparison between surgeries were performed.

RESULTS

There was no significant contrast sensitivity change during the one-year follow-up measurements neither for LASIK nor for PRK eyes. The comparison between procedures showed no differences at 12 months postoperative.

CONCLUSIONS

The present data showed similar contrast sensitivities during one-year follow-up of wave-front guided refractive surgeries. Moreover, one year postoperative data showed no differences in the effects of either wavefront-guided LASIK or wavefront-guided PRK on the luminance and chromatic spatial contrast sensitivity functions.

Для цитирования: Barboni Mirella Telles Salgueiro, Feitosa-Santana Claudia, Barreto Junior Jackson, Lago Marcos, Bechara Samir Jacob, Alves Milton Ruiz, Ventura Dora Fix. Longitudinal measurements of luminance and chromatic contrast sensitivity: comparison between wavefront-guided LASIK and contralateral PRK for myopia.. Arquivos brasileiros de oftalmologia. 2013. DOI: 10.1590/s0004-27492013000500003.