MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20131029-02

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2013

Early clinical outcomes of wavefront-guided myopic LASIK treatments using a new-generation hartmann-shack aberrometer.

Schallhorn Steven, Brown Mitch, Venter Jan, Teenan David, Hettinger Keith, Yamamoto Hiromi

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To provide an initial retrospective evaluation of early postoperative outcomes after wavefront-guided myopic LASIK using a new-generation Hartmann-Shack wavefront sensor.

METHODS

A noncomparative, retrospective study of 243 eyes of 126 patients that underwent primary wavefront-guided LASIK, using wavefront data obtained with a new Hartmann-Shack aberrometer (iDesign Advanced WaveScan aberrometer; Abbott Medical Optics, Inc., Santa Ana, CA). Visual acuity, refraction, and patient satisfaction were evaluated 1 month after surgery.

RESULTS

The manifest spherical equivalent was reduced from -3.28 ± 1.79 diopters (D) (range: -9.88 to -0.38 D) before surgery to -0.03 ± 0.29 D (range: -1.00 to +1.25 D) 1 month after surgery. The manifest spherical equivalent was within 0.50 and 1.00 D of target in 93.0% and 99.6% of eyes, respectively. Manifest astigmatism preoperatively (-0.72 ± 0.67 [range: 0.0 to -5.00 D]) was reduced to -0.14 ± 0.20 (range: 0.0 to -1.00 D) at 1 month and the vector-derived correction ratio (surgically induced refractive change/intended refractive correction) was 1.02 ± 0.30. Uncorrected distance visual acuity of 20/16, 20/20, and 20/25 or better was achieved in 79.0%, 93.4%, and 96.7% of eyes, respectively. No eyes lost two or more lines of corrected distance visual acuity, whereas a gain of one or more lines was observed in 14.0%. Most patients (98.5%) reported that they were satisfied with the outcome of their procedure.

CONCLUSIONS

Wavefront-guided LASIK using the new aberrometer in this retrospective evaluation was effective, safe, and predictable in the early postoperative time period for the correction of myopia with high patient satisfaction.

Для цитирования: Schallhorn Steven, Brown Mitch, Venter Jan, Teenan David, Hettinger Keith, Yamamoto Hiromi. Early clinical outcomes of wavefront-guided myopic LASIK treatments using a new-generation hartmann-shack aberrometer.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2013. DOI: 10.3928/1081597x-20131029-02.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.