MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2013.08.009

Медицинская библиотека · American journal of ophthalmology · 2013

Extended depth of focus with induced spherical aberration in light-adjustable intraocular lenses.

Villegas Eloy A, Alcón Encarna, Mirabet Sandra, Yago Inés, Marín José María, Artal Pablo

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the quality of vision and depth of focus induced by controlled amounts of negative spherical aberration in patients implanted bilaterally with light-adjustable intraocular lenses.

DESIGN

Prospective, nonrandomized clinical trial.

METHODS

Seventeen patients were implanted and treated with appropriate spatial irradiance light profiles. One eye was set for emmetropia, and the fellow eye received an additional aspheric light treatment to induce controlled amounts of negative spherical aberration. We used a Hartmann-Shack sensor to measure the eye's refraction and aberrations for a 4-mm pupil diameter. Decimal visual acuity (VA) was measured using a micro-display placed at 10 m, 60 cm, 40 cm, and 30 cm.

RESULTS

Eyes treated with aspheric profiles were divided into 2 groups depending on the final amount of induced negative spherical aberration: low [-0.05, -0.10 μm] and high [-0.13, -0.23 μm]. In both groups, the mean uncorrected decimal VA at 60 cm was over 0.90. In the first group, distance VA was 0.97 ± 0.16, but in the second group it was lower (0.76 ± 0.16). As expected, the VA for nearer distances is higher in the eyes with a larger magnitude of spherical aberration (P value < .01): 0.94 ± 0.10 and 0.73 ± 0.16 at 40 and 30 cm, respectively, in comparison with 0.71 ± 0.15 and 0.50 ± 0.14. Binocular summation with the fellow eye, adjusted for emmetropia, produces an excellent binocular distance VA (>1.10) in both groups.

CONCLUSIONS

Controlled amounts of negative spherical aberration and defocus can be induced in eyes implanted with adjustable intraocular lenses to enhance near vision.

Для цитирования: Villegas Eloy A, Alcón Encarna, Mirabet Sandra, Yago Inés, Marín José María, Artal Pablo. Extended depth of focus with induced spherical aberration in light-adjustable intraocular lenses.. American journal of ophthalmology. 2013. DOI: 10.1016/j.ajo.2013.08.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.