MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2013.04.044

Медицинская библиотека · Journal of cataract and refractive surgery · 2013

Visual outcomes comparison of 2 femtosecond laser platforms for laser in situ keratomileusis.

Ang Marcus, Mehta Jodhbir S, Rosman Mohamad, Li Lim, Koh Jane C W, Htoon Hla M, Tan Donald, Chan Cordelia

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the efficacy, predictability, and safety outcomes of 2 femtosecond laser platforms for flap creation during laser in situ keratomileusis (LASIK) for myopia and myopic astigmatism.

SETTING

Singapore National Eye Centre, Singapore.

DESIGN

Retrospective case review.

METHODS

In this single-center multisurgeon study, patients had LASIK with flaps created using a Visumax 500 kHz or Intralase 60 kHz femtosecond laser system. Ablation was performed with the Wavelight Allegretto Eye-Q 400 Hz excimer laser in all patients. Preoperative and 3-month postoperative manifest refraction, attempted treatment spherical equivalent (SE), visual acuity, and complications were compared.

RESULTS

The 500 kHz femtosecond laser group comprised 381 patients (381 eyes) and the 60 kHz femtosecond laser group, 362 patients (362 eyes). Three months postoperatively, the uncorrected distance visual acuity was 20/40 or better in 99.1% of eyes in the 60 kHz laser group and 99.4% of eyes in the 500 kHz laser group (P=.678). Regarding predictability, 98.6% of eyes and 97.4% of eyes, respectively, were within ± 1.0 diopter of the attempted SE correction postoperatively (P=.228). The safety index was similar in the 60 kHz laser group and the 500 kHz laser group (mean 1.06 ± 0.16 [SD] versus 1.05 ± 0.14) (P=.321).

CONCLUSION

The safety, predictability, and efficacy profiles of the 500 kHz femtosecond platform for LASIK were excellent and comparable to those of the 60 kHz platform.

Для цитирования: Ang Marcus, Mehta Jodhbir S, Rosman Mohamad, Li Lim, Koh Jane C W, Htoon Hla M, Tan Donald, Chan Cordelia. Visual outcomes comparison of 2 femtosecond laser platforms for laser in situ keratomileusis.. Journal of cataract and refractive surgery. 2013. DOI: 10.1016/j.jcrs.2013.04.044.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.