MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2013.05.042

Медицинская библиотека · Journal of cataract and refractive surgery · 2013

Comprehensive anterior segment normal values generated by rotating Scheimpflug tomography.

Gilani Fatimah, Cortese Michael, Ambrósio Renato R, Lopes Bernardo, Ramos Isaac, Harvey Erin M, Belin Michael W

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To identify normal values for tomographic parameters that are considered useful in screening patients for refractive surgery.

SETTING

Private center, Albany, New York, USA.

DESIGN

Database study.

METHODS

A Pentacam HR Scheimpflug system was used to examine 1 randomly selected eye of patients to determine normal values of 21 parameters considered the most clinically applicable for surgical screening. Normality of data was evaluated using the Kolmogorov-Smirnov test. Statistical analyses were performed using the Student t test to compare means and the 2-paired sample Wilcoxon signed-rank test. Results are displayed in 95.0% and 97.5% confidence intervals (CIs).

RESULTS

The study evaluated 341 adults. High-end outliers at the 97.5% CI were 46.1 diopters (D) for flat keratometry (K), 47.4 D for steep K, 3.4 D for astigmatism, 3.8 μm for anterior chamber depth, 4 μm for front apical elevation, 5 μm for front elevation at the thinnest point, and 12 μm for front elevation in the central 4.0 mm. Respective posterior elevation values were 7 μm, 13 μm, and 25 μm, with a progression index maximum of 1.53 and mean of 1.19, difference between apical and thinnest pachymetric reading of 7 μm, a maximum K of 48.2 D, and an inferior-superior ratio of 1.44 D. Low-end outliers were a maximum Ambrósio relational thickness of 335 and a mean of 425, minimum pachymetry of 479 μm, thickness at the apex of 481 μm, and central 4.0 mm corneal volume of 6.31 mm(3).

CONCLUSION

Scheimpflug-derived corneal tomography identified key refractive surgery parameters that may be useful in screening refractive surgical patients.

Для цитирования: Gilani Fatimah, Cortese Michael, Ambrósio Renato R, Lopes Bernardo, Ramos Isaac, Harvey Erin M, Belin Michael W. Comprehensive anterior segment normal values generated by rotating Scheimpflug tomography.. Journal of cataract and refractive surgery. 2013. DOI: 10.1016/j.jcrs.2013.05.042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.