MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2013.04.041

Медицинская библиотека · Journal of cataract and refractive surgery · 2013

Surgical outcomes after application of a liquid adhesive ocular bandage to clear corneal incisions during cataract surgery.

Uy Harvey S, Kenyon Kenneth R

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the anatomic and refractive outcomes in eyes having phacoemulsification with 1 of 3 clear corneal incision (CCI) closure methods.

SETTING

Ambulatory surgical center, Makati, Philippines.

DESIGN

Prospective randomized clinical trial.

METHODS

Patients having phacoemulsification cataract surgery had wound closure using no additional treatment (control), a single 10-0 nylon suture, or a liquid adhesive ocular bandage (Ocuseal). The main outcome measures were wound-edge closure rates, surgically induced astigmatism (SIA), foreign-body sensation, and intraocular pressure (IOP) 1, 3, 5, 7, and 14 days postoperatively.

RESULTS

The study evaluated 90 eyes. There was a significant improvement in wound-edge closure rates in the suture group and the ocular bandage group compared with the control group (P<.001). A significant increase in SIA occurred in the sutured group but not in the control or ocular bandage groups (P<.001). The ocular bandage group had significantly less foreign-body sensation than the control and suture groups (P<.001). There were no significant differences in IOP between the groups (P=.515).

CONCLUSIONS

The liquid adhesive ocular bandage resulted in improved wound-edge closure, reduced SIA, and diminished foreign-body sensation. Suturing was associated with improved wound-edge closure but increased SIA and foreign-body sensation. Unsutured incisions led to delayed wound-edge closure and increased foreign-body sensation.

Для цитирования: Uy Harvey S, Kenyon Kenneth R. Surgical outcomes after application of a liquid adhesive ocular bandage to clear corneal incisions during cataract surgery.. Journal of cataract and refractive surgery. 2013. DOI: 10.1016/j.jcrs.2013.04.041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.