Shape of the anterior cornea: comparison of height data from 4 corneal topographers.

de Jong Tim, Sheehan Matthew T, Dubbelman Michiel, Koopmans Steven A, Jansonius Nomdo M

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the ability of clinical corneal topographers to describe the shape of the anterior cornea for optical modeling.

SETTING

University Medical Center Groningen, Groningen, Netherlands.

DESIGN

Cross-sectional study.

METHODS

The anterior corneal shape of healthy subjects was assessed with 4 topographers (Atlas Placido disk, Galilei dual Scheimpflug, Orbscan scanning slit, Pentacam single Scheimpflug). Exported height data were fit with Zernike polynomials. Mean values with the standard deviation, interdevice variability, and test-retest variability were determined for the defocus Z(2,0), astigmatism Z(2,-2) and Z(2,2), coma Z(3,-1) and Z(3,1), and spherical aberration Z(4,0) coefficients for 5.5 mm and 8.0 mm diameters.

RESULTS

At 5.5 mm, the single Scheimpflug topographer showed the smallest coefficient of repeatability; 0.31 μm for Z(2,0); 0.40 and 0.34 μm for Z(2,-2) and Z(2,2), respectively; 0.15 and 0.11 μm for Z(3,-1) and Z(3,1), respectively; and 0.08 μm for Z(4,0); the other topographers showed up to 10 times larger coefficients of repeatability. The (unsigned) mean differences between the topographers were in the range of 0.20 to 1.21 μm for Z(2,0); 0.02 to 0.31 μm and 0.06 to 0.42 μm for Z(2,-2) and Z(2,2), respectively; 0.03 to 0.18 μm and 0.03 to 0.35 μm for Z(3,-1) and Z(3,1), respectively; and 0.00 to 0.14 μm for Z(4,0). The Placido-disk topographer and single Scheimpflug topographer data corresponded best. Similar trends were found at 8.0 mm.

CONCLUSION

Test-retest variability hampered a detailed description of the anterior corneal shape at the level of individual subjects; interdevice variability compromises the exchangeability of the devices.

FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: de Jong Tim, Sheehan Matthew T, Dubbelman Michiel, Koopmans Steven A, Jansonius Nomdo M. Shape of the anterior cornea: comparison of height data from 4 corneal topographers.. Journal of cataract and refractive surgery. 2013. DOI: 10.1016/j.jcrs.2013.04.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.