MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-013-9833-4

Медицинская библиотека · International ophthalmology · 2013

Photorefractive keratectomy for myopia and myopic astigmatism correction using the WaveLight Allegretto Wave Eye-Q excimer laser system.

Costa Esmeralda, Franqueira Nuno, Rosa Andreia M, Tavares Cristina, Quadrado Maria J, Lobo Conceição, Murta Joaquim N

СтатьяПеревод пока не подготовлен

Аннотация

To analyze photorefractive keratectomy (PRK) outcomes in myopia and myopic astigmatism correction using the WaveLight Allegretto Wave Eye-Q(®) excimer laser system (WaveLight Laser Technologie AG, Erlangen, Germany). 222 eyes of 151 patients underwent PRK (mean age 33.5 ± 6.8 years). Pre-operative best spectacle-corrected visual acuity (BSCVA) ranged from 0.4 to -0.1 logMAR (mean -0.03 ± 0.06). Mean spherical equivalent (SE) was -3.29 ± 1.20 D. Efficacy, predictability and safety were evaluated. Minimum follow-up was 3 months. Accountability at 3 and 6 months was 100 and 54 %, respectively (median follow-up 5 months, mean 5.2 ± 2.6 months). At 3 months, mean uncorrected visual acuity (UCVA) was -0.02 ± 0.07 logMAR, BSCVA -0.03 ± 0.05 logMAR, efficacy index 0.98 and safety index 1.02. UCVA was ≥20/16 in 40.1 %, ≥20/20 in 86.5 % and ≥20/25 in 98.2 %. Mean SE was -0.02 ± 0.20 D. Residual refractive error was ± 0.13 D in 81.5 %, ± 0.25 D in 88.7 % and ± 0.50 D in 97.7 %. At 6 months, outcomes were similar: mean UCVA was -0.02 ± 0.07 logMAR, BSCVA -0.03 ± 0.06 logMAR, efficacy index 1.00 and safety index 1.03. UCVA was ≥20/16 in 43.7 %, ≥20/20 in 86.6 % and ≥20/25 in 96.6 %. Mean SE was -0.02 ± 0.17 D. Residual refractive error was ± 0.13 D in 86.6 %, ± 0.25 D in 93.3 % and ± 0.50 D in 98.3 %. Refractive stability was achieved at 3 months. No patient lost more than one line of BSCVA. There were no retreatments. The WaveLight Allegretto Wave Eye-Q is effective, predictable and safe in low-to-moderate myopia and myopic astigmatism PRK correction.

Для цитирования: Costa Esmeralda, Franqueira Nuno, Rosa Andreia M, Tavares Cristina, Quadrado Maria J, Lobo Conceição, Murta Joaquim N. Photorefractive keratectomy for myopia and myopic astigmatism correction using the WaveLight Allegretto Wave Eye-Q excimer laser system.. International ophthalmology. 2013. DOI: 10.1007/s10792-013-9833-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.