BACKGROUND

Long-term use of immunosuppressants is associated with significant morbidity and mortality in transplant recipients. A simple whole blood assay that has U.S. Food and Drug Administration clearance directly assesses the net state of immune function of allograft recipients for better individualization of therapy. A meta-analysis of 504 solid organ transplant recipients (heart, kidney, kidney-pancreas, liver and small bowel) from 10 U.S. centers was performed using the Cylex ImmuKnow assay.

METHODS

Blood samples were taken from recipients at various times posttransplant and compared with clinical course (stable, rejection, infection). In this analysis, 39 biopsy-proven cellular rejections and 66 diagnosed infections occurred. Odds ratios of infection or rejection were calculated based on measured immune response values.

RESULTS

A recipient with an immune response value of 25 ng/ml adenosine triphosphate (ATP) was 12 times (95% confidence of 4 to 36) more likely to develop an infection than a recipient with a stronger immune response. Similarly, a recipient with an immune response of 700 ng/ml ATP was 30 times (95% confidence of 8 to 112) more likely to develop a cellular rejection than a recipient with a lower immune response value. Of note is the intersection of odds ratio curves for infection and rejection in the moderate immune response zone (280 ng/ml ATP). This intersection of risk curves provides an immunological target of immune function for solid organ recipients.

CONCLUSION

These data show that the Cylex ImmuKnow assay has a high negative predictive value and provides a target immunological response zone for minimizing risk and managing patients to stability.

Для цитирования: Kowalski Richard J, Post Diane R, Mannon Roslyn B, Sebastian Anthony, Wright Harlan I, Sigle Gary, Burdick James, Elmagd Kareem Abu, Zeevi Adriana, Lopez-Cepero Mayra, Daller John A, Gritsch H Albin, Reed Elaine F, Jonsson Johann, Hawkins Douglas, Britz Judith A. Assessing relative risks of infection and rejection: a meta-analysis using an immune function assay.. Transplantation. 2006. DOI: 10.1097/01.tp.0000234837.02126.70.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.