MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.transproceed.2005.05.034

Медицинская библиотека · Transplantation proceedings · 2005

Evaluation of a new immunoassay to measure sirolimus blood concentrations compared to a tandem mass-spectrometric chromatographic analysis.

Fillée C, Mourad M, Squifflet J P, Malaise J, Lerut J, Reding R, Borghgraef P, Vanbinst R, Wallemacq P E

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

A new immunoassay of sirolimus based on the microparticle enzyme immunoassay (MEIA) principle has been developed with collaboration of Abbott Diagnostics. Laboratories and Axis-Shield. Our laboratory evaluated this new assay on 153 whole blood samples (EDTA) drawn from a population of renal (n = 141) and hepatic (n = 12) transplant patients. Each blood sample was analyzed simultaneously by MEIA (Y) and by a reference method (X) used routinely in our laboratory, namely, liquid chromatography tandem mass spectrometry (LC-MS/MS). The statistical analysis of Passing-Bablok produced the following results: Spearman r value = 0.95, slope = 1.15 and intercept with the Y axis = +0.2 ng/mL. The observed global overestimation of 15% compared to the reference method could be explained by the cross-reactivity of sirolimus metabolites with the antibody. A complementary analysis taking into account the transplanted organ (kidney versus hepatic) did not show any significant difference between the populations, most likely owing to the low number of hepatic transplantation samples. The analytical performance of the MEIA method showed CV < or =10% and a limit of quantification of 1.5 ng/mL, which were acceptable for routine clinical monitoring. In conclusion, the MEIA method has shown robust, stable, reproducible, features with an excellent correlation with the reference LC-MS/MS method.

Для цитирования: Fillée C, Mourad M, Squifflet J P, Malaise J, Lerut J, Reding R, Borghgraef P, Vanbinst R, Wallemacq P E. Evaluation of a new immunoassay to measure sirolimus blood concentrations compared to a tandem mass-spectrometric chromatographic analysis.. Transplantation proceedings. 2005. DOI: 10.1016/j.transproceed.2005.05.034.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.