MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40729-021-00320-3

Медицинская библиотека · International journal of implant dentistry · 2021

Does the macro design of an implant affect the accuracy of template-guided implantation? A prospective clinical study.

Schnutenhaus Sigmar, Edelmann Cornelia, Rudolph Heike

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

An implant prosthesis aims to ensure the best possible rehabilitation of function and esthetics following tooth loss. Template-guided insertion is used to achieve an optimal position of the implant with regard to prosthetic restorability, bone availability, and condition of the surrounding soft tissues. The accuracy of template-guided implant placement is subject to various influencing factors. The clinically achievable accuracy depending on the macro design of the implant body was investigated in this prospective clinical study.

MATERIAL AND

METHODS

In this prospective clinical study, 20 implants were placed in 20 patients. The implant had a pronounced conical outer geometry (Conelog ProgressiveLine, Camlog Wimsheim, Germany). Data from a study using an implant with a distinct cylindrical outer geometry were used as a comparison group (Conelog ScrewLine, Camlog, Wimsheim, Germany). The clinically achieved implant position was compared with the planned position.

RESULTS

The evaluation of the two-dimensional deviations in direction resulted in the following mean values (standard deviation) at the shoulder: 0.42 mm (0.33) in the buccolingual direction, 0.27 mm (0.25) in the mesiodistal direction, and 0.68 mm (0.55) in the apicocoronal direction. The mean angular deviation was 4.1° (2.3). The three-dimensional (3D) deviation was 0.94 mm (0.53) at the shoulder and 1.36 mm (0.62) at the apex of the implant. Significant differences between implants with different macro designs were found in the apicocoronal direction. In connection to this, a significant 3D deviation was found at the implant shoulder.

CONCLUSIONS

Significant differences in height were found between the groups. The study had shown that the macro design of an implant has no influence on accuracy in all other directions. Overall, the implants showed a high level of accuracy and a low variation in values. The values were in the range determined by the template-guided insertion system in numerous other investigations. This provides good predictability of prosthetic rehabilitation.

TRIAL REGISTRATION: German Register for Clinical Studies (DRKS-ID: DRKS000018939 ). Date of registration: November 11, 2019.

Для цитирования: Schnutenhaus Sigmar, Edelmann Cornelia, Rudolph Heike. Does the macro design of an implant affect the accuracy of template-guided implantation? A prospective clinical study.. International journal of implant dentistry. 2021. DOI: 10.1186/s40729-021-00320-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.