MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mus.27140

Медицинская библиотека · Muscle & nerve · 2020

Reduced plasmablast frequency is associated with seronegative myasthenia gravis.

Guptill Jeffrey T, Barfield Richard, Chan Cliburn, Russo Melissa A, Emmett Doug, Raja Shruti, Massey Janice M, Juel Vern C, Hobson-Webb Lisa D, Gable Karissa L, Gonzalez Natalia, Hammett Alex, Howard James F, Chopra Manisha, Kaminski Henry J, Siddiqi Zaeem A, Migdal Mattingly, Yi John S

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

The immunopathology of autoimmune seronegative myasthenia gravis (SN MG) is poorly understood. Our objective was to determine immune profiles associated with a diagnosis of SN MG.

METHODS

We performed high-dimensional flow cytometry on blood samples from SN MG patients (N = 68), healthy controls (N = 46), and acetylcholine receptor antibody (AChR+) MG patients (N = 27). We compared 12 immune cell subsets in SN MG to controls using logistic modeling via a discovery-replication design. An exploratory analysis fit a multinomial model comparing AChR+ MG and controls to SN MG.

RESULTS

An increase in CD19+ CD20- CD38hi plasmablast frequencies was associated with lower odds of being a SN MG case in both the discovery and replication analyses (discovery P-value = .0003, replication P-value = .0021). Interleukin (IL) -21 producing helper T cell frequencies were associated with a diagnosis of AChR+ MG (P = .004).

CONCLUSIONS

Reduced plasmablast frequencies are strongly associated with a SN MG diagnosis and may be a useful diagnostic biomarker in the future.

Для цитирования: Guptill Jeffrey T, Barfield Richard, Chan Cliburn, Russo Melissa A, Emmett Doug, Raja Shruti, Massey Janice M, Juel Vern C, Hobson-Webb Lisa D, Gable Karissa L, Gonzalez Natalia, Hammett Alex, Howard James F, Chopra Manisha, Kaminski Henry J, Siddiqi Zaeem A, Migdal Mattingly, Yi John S. Reduced plasmablast frequency is associated with seronegative myasthenia gravis.. Muscle & nerve. 2020. DOI: 10.1002/mus.27140.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.