DOI 10.1016/j.amjcard.2024.07.026

Медицинская библиотека · The American journal of cardiology · 2024

Impact of Small Aortic Annuli on the Performance of Transcatheter Aortic Valve Replacement Bioprostheses: An Updated Meta-Analysis of Recent Studies.

Di Pietro Gianluca, Improta Riccardo, Bruno Francesco, De Filippo Ovidio, Leone Pier Pasquale, Nebiolo Marco, Giacobbe Federico, Caporusso David, Birtolo Lucia Ilaria, Ielasi Alfonso, Mohamed Abdel-Wahab, Ho Kay Woon, Meguro Kentaro, Ferrara Jerome, Waksman Ron, Pilgrims Thomas, McKay Raymond G, Seiffert Moritz, Massimo Mancone, De Ferrari Gaetano Maria, D'Ascenzo Fabrizio

СтатьяМетаанализОбзорПеревод пока не подготовлен

Аннотация

A metanalysis of available randomized controlled trials and observational studies comparing self-expanding (SE) and balloon-expandable (BE) bioprostheses in patients with small aortic annulus and aortic stenosis for short- and midterm hemodynamic and clinical outcomes was performed. A total of 21 studies with a total 8,647 patients (SE: n = 4,336 patients vs BE: n = 4,311 patients) were included. SE bioprostheses had a lower postoperative mean gradient at 30 days (Mean Difference [MD] -5.16, 95% confidence interval [CI] 4.7 to 5.5, p <0.001) and at 1 year (MD -6.6, 95%CI 6.1 to 7.03, p <0.001), with a larger indexed effective orifice area (0.17, 95% CI 0.13 to 0.22, p <0.001 and 0.17, 95% CI 0.08 to 0.27, p <0.001) at both time intervals. BE bioprostheses had a higher risk of 30-day and 1-year severe prosthesis-patient mismatch (risk ratio [RR] 1.07, 95% CI 1.04 to 1.09, p <0.001; RR 1.07, 95% CI 1.04 to 1.11, p <0.001). The 30-day and 1 year paravalvular leaks (RR 0.99, 95% CI 0.98 to 0.99, p <0.001; RR 0.89, 95% CI 0.82 to 0.95, p <0.001) and permanent pacemaker implantation (RR 0.97, 95% CI 0.94 to 0.99, p 0.01, I2 = 40%,) were lower in the BE group. BE bioprostheses were associated with a lower risk of in-hospital stroke (RR 0.99, 95% CI 0.98 to 1, p = 0.01). In conclusion, in patients with small aortic annulus and aortic stenosis, SE bioprostheses have superior hemodynamic performance but higher rates of paravalvular leak, permanent pacemaker implantation, and in-hospital stroke. BE bioprostheses were associated with a higher risk of severe prosthesis-patient mismatch.

Для цитирования: Di Pietro Gianluca, Improta Riccardo, Bruno Francesco, De Filippo Ovidio, Leone Pier Pasquale, Nebiolo Marco, Giacobbe Federico, Caporusso David, Birtolo Lucia Ilaria, Ielasi Alfonso, Mohamed Abdel-Wahab, Ho Kay Woon, Meguro Kentaro, Ferrara Jerome, Waksman Ron, Pilgrims Thomas, McKay Raymond G, Seiffert Moritz, Massimo Mancone, De Ferrari Gaetano Maria, D'Ascenzo Fabrizio. Impact of Small Aortic Annuli on the Performance of Transcatheter Aortic Valve Replacement Bioprostheses: An Updated Meta-Analysis of Recent Studies.. The American journal of cardiology. 2024. DOI: 10.1016/j.amjcard.2024.07.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.