DOI 10.1016/j.echo.2024.06.017
Dobutamine Stress Echocardiography in Low-Gradient Aortic Stenosis.
Аннотация
IMPORTANCE
Guidelines recommend the use of dobutamine stress echocardiography (DSE) in patients with low-gradient aortic stenosis (AS) and left ventricular ejection fraction (LVEF) <50%. However, a paucity of DSE data exists when LVEF >35%.
OBJECTIVE
To examine the diagnostic accuracy of DSE in patients with low-gradient AS with a wide range of LVEF and to examine the interaction between the diagnostic accuracy of DSE and LVEF.
DESIGN, SETTING, AND
PARTICIPANTS
Patients with mean gradient <40 mm Hg, aortic valve area <1.0 cm2, and stroke volume index ≤35 mL/m2 undergoing DSE and cardiac computer tomography (C-CT) were identified from 3 prospectively collected patient cohorts and stratified according to LVEF: LVEF<35%, LVEF 35% to 50%, and LVEF>50%.
EXPOSURE: Dobutamine stress echocardiography and C-CT were performed on patients with low-gradient AS.
MAIN OUTCOMES AND MEASURES: Severe AS was defined as aortic valve calcification score ≥2,000 arbitrary units (AU) among men and ≥1,200 AU for women on C-CT.
RESULTS
Of 221 patients included in the study, 78 (35%) presented with LVEF <35%, 67 (30%) with LVEF 35% to 50%, and 76 (34%) with LVEF >50%. Mean-gradient and aortic valve peak velocity during DSE showed significant diagnostic heterogeneity between LVEF groups, being most precise when LVEF <35% (both areas under the curve [AUC] = 0.90), albeit with optimal thresholds of 30 mm Hg and 377 cm/sec and a limited diagnostic yield in patients with LVEF ≥35% (AUC = 0.67 and 0.66 in LVEF 35% to 50% and AUC = 0.65 and 0.60 in LVEF ≥50%). Using guideline thresholds led to a sensitivity/specificity of 49%/84% for all patients with LVEF <50%.
CONCLUSION AND RELEVANCE: While DSE is safe and leads to an increase in stroke volume in patients with low-gradient AS regardless of LVEF, the association between DSE gradients and AS severity assessed by C-CT demonstrates important heterogeneity depending on LVEF, with the highest accuracy in patients with LVEF <35%.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.