MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1212/wnl.0000000000010619

Медицинская библиотека · Neurology · 2020

Comparison of ice pack test and single-fiber EMG diagnostic accuracy in patients referred for myasthenic ptosis.

Giannoccaro Maria Pia, Paolucci Matteo, Zenesini Corrado, Di Stasi Vitantonio, Donadio Vincenzo, Avoni Patrizia, Liguori Rocco

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the diagnostic accuracy of ice pack test (IPT) and single-fiber EMG (SF-EMG) in patients with suspected ocular myasthenia (OM) presenting with ptosis.

METHODS

We studied consecutive patients referred for the clinical suspicion of OM. Patients underwent IPT and stimulated SF-EMG on the orbicularis oculi muscle. Receiver operating characteristic curve analysis was performed to determine the accuracy of IPT, SF-EMG, and their combination.

RESULTS

We included 155 patients, 102 with OM and 53 with other diagnosis (OD). The IPT had a sensitivity of 86% (95% confidence interval [CI] 79-93) and a specificity of 79% (95% CI 68-90). SF-EMG showed a sensitivity of 94% (95% CI 89-98) and a specificity of 79% (95% CI 68-90). Overall, IPT and SF-EMG showed discordant results in 30 cases, 16 OM and 14 OD. The combination of IPT and SF-EMG, using the positivity of at least one test for OM diagnosis, increased the sensitivity to 98% (95% CI 95-100), reducing the specificity to 66% (95% CI 53-78), whereas using the positivity of both tests, we obtained a sensitivity of 82% (95% CI 75-90) and a specificity of 92% (95% CI 85-99). The negativity of both tests had a 94% (95% CI 87-100) negative predictive value. Comparison of the areas under the curve showed no differences in the diagnostic accuracy of IPT, SF-EMG, and their combinations.

CONCLUSIONS

IPT and SF-EMG have similar diagnostic accuracy in patients with OM presenting with ptosis. The negativity of both tests strongly suggests another diagnosis.

CLASSIFICATION OF EVIDENCE: This study provides Class I evidence that both the IPT and SF-EMG accurately identify patients with OM.

Для цитирования: Giannoccaro Maria Pia, Paolucci Matteo, Zenesini Corrado, Di Stasi Vitantonio, Donadio Vincenzo, Avoni Patrizia, Liguori Rocco. Comparison of ice pack test and single-fiber EMG diagnostic accuracy in patients referred for myasthenic ptosis.. Neurology. 2020. DOI: 10.1212/wnl.0000000000010619.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.