MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mbp.0000000000000755

Медицинская библиотека · Blood pressure monitoring · 2025

Validation of the YuWell YE990 medical automatic electronic blood pressure monitor according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard (ISO 81060-2:2018/Amd.1:2020).

Xu Dongju, Tang Haiqin, Wang Cuidi, Cheng Hui, Wu Wenhui, Lu Qi, Liu Hejun

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

To validate the accuracy of the YuWell YE990 automated oscillometric upper-arm medical blood pressure (BP) monitor in adults according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal standards (ISO 81060-2:2018 and Amendment 1:2020). Participants were recruited to meet the age, sex, BP, and cuff distribution criteria of the AAMI/ESH/ISO standards. BP was measured using a mercury sphygmomanometer (reference device) and YE990 (test device) following a same-arm sequential protocol with two trained observers and a supervisor. Bland-Altman plots were used to assess agreement, and scatter plots were used to assess the performance across varying arm sizes. Ninety-nine subjects were recruited and 85 were analyzed. The YE990 passed the accuracy requirements of the AAMI/ESH/ISO standards, with mean differences of 0.4 ± 6.31 mmHg for systolic BP and -0.9 ± 6.28 mmHg for diastolic BP for validation criterion 1. For validation criterion 2, the SD of the average BP difference between the test device and reference BP per subject was 5.00/5.70 mmHg (systolic/diastolic). YuWell YE990 meets the AAMI/ESH/ISO universal accuracy standard (ISO 81060-2:2018+Amd.1:2020) and is recommended for clinical use.

Для цитирования: Xu Dongju, Tang Haiqin, Wang Cuidi, Cheng Hui, Wu Wenhui, Lu Qi, Liu Hejun. Validation of the YuWell YE990 medical automatic electronic blood pressure monitor according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard (ISO 81060-2:2018/Amd.1:2020).. Blood pressure monitoring. 2025. DOI: 10.1097/mbp.0000000000000755.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.