Community Health Workers Equipped with an mHealth Application Can Accurately Diagnose Hypertension in Rural Guatemala.

Duffy Sean, Valley Taryn McGinn, Chavez Alejandro, Aguilar Valerie, Villalobos Juan Aguirre, Tetreault Kaitlin, Chen Guanhua, White Elizabeth, Bermudez-Cañete Alvaro, Dang Do, Cornfield Julie, Letona Yoselin, Tun Rafael

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

Hypertension is a leading global cause of morbidity and mortality and is increasing in low- and middle-income countries, where unawareness of hypertension is a primary obstacle to management. Community health workers (CHWs) in combination with mobile health (mHealth) tools are increasingly used in LMIC health systems to strengthen primary care infrastructure. In this study, we applied this care model to hypertension in rural Guatemala by comparing the accuracy of CHWs equipped with an mHealth clinical decision support application in diagnosing hypertension to concurrent physician evaluation.

METHODS

We performed a prospective diagnostic accuracy study in which adults from rural Guatemalan communities were assessed independently by a CHW aided by a mHealth application and a physician. Assessment included medical history; measurement of blood pressure, height and weight; and determination of hypertension status. CHW-physician agreement on hypertension status and past medical history elements was assessed by Kappa analysis and proportional agreement, with a priori thresholds of Kappa = 0.61 and agreement of 90%. Agreement on patient measurements was evaluated using Bland-Altman and regression analyses.

RESULTS

Of 359 participants enrolled, 47 (13%) were confirmed to have hypertension and another 11 (3%) had possible hypertension. CHW-physician agreement was high for hypertension diagnosis, with Kappa = 0.8 (95% CI = 0.72, 0.88) and overall agreement 92.8% (95% CI = 90.1%, 95.4%). Bland-Altman analysis showed small biases toward lower systolic blood pressure, higher height, and lower BMI measurements by CHWs. Most patient history characteristics showed moderate to almost perfect (Kappa: 0.41-1) agreement between physicians and CHWs.

CONCLUSIONS

In this study based in rural Guatemala, CHWs using a mHealth clinical decision support application were found to screen adult patients for hypertension with similar accuracy to a physician. This approach could be adapted to other low-resource settings to reduce the burden of undiagnosed and untreated hypertension.

Для цитирования: Duffy Sean, Valley Taryn McGinn, Chavez Alejandro, Aguilar Valerie, Villalobos Juan Aguirre, Tetreault Kaitlin, Chen Guanhua, White Elizabeth, Bermudez-Cañete Alvaro, Dang Do, Cornfield Julie, Letona Yoselin, Tun Rafael. Community Health Workers Equipped with an mHealth Application Can Accurately Diagnose Hypertension in Rural Guatemala.. Global heart. 2025. DOI: 10.5334/gh.1423.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.