MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euae278

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024

Anatomical vs. electrophysiological approach for ablation of premature ventricular contractions originating from the left ventricular summit (ISESHIMA-SUMMIT Study).

Watanabe Ryuta, Nagashima Koichi, Shirai Yasuhiro, Kitai Takayuki, Okada Takuya, Tokuda Michifumi, Fukunaga Masato, Onuki Koumei, Nakatani Yosuke, Yoshimura Shingo, Takatsuki Seiji, Hashimoto Kenji, Yamashita Shuhei, Kato Masafumi, Uchida Fumiya, Fukamizu Seiji, Hojo Rintaro, Mori Hitoshi, Matsumoto Kazuhisa, Kato Hiroyuki, Suga Kazumasa, Sakurai Taku, Sakamoto Yusuke, Hayashi Tatsuya, Wakamatsu Yuji, Hirata Shu, Hirata Moyuru, Sawada Masanaru, Kurokawa Sayaka, Okumura Yasuo

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: Catheter ablation (CA) of idiopathic ventricular arrhythmias (VAs) from the epicardial left ventricular summit is challenging. The endocardial approach targets two sites: the endocardial closest site (ECS) to the epicardial earliest activation site (epi-EAS) and the endocardial earliest activation site (endo-EAS). We aimed to differentiate between cases where CA at the ECS was effective and where CA at the endo-EAS yielded success.

METHODS AND

RESULTS

Fifty-eight patients (47 men; age 60 ± 13 years) were analysed with VAs in which the EAS was observed in the coronary venous system (CVS). Overall, VAs were successfully eliminated in 42 (72%) patients: 8 in the CVS, 8 where the ECS matched with the endo-EAS, 11 at the ECS, and 15 at the endo-EAS. A successful ECS ablation was associated with a shorter epi-EAS-ECS distance (10.2 ± 4.7 vs. 18.8 ± 5.3 mm; P < 0.001) and shorter epi-EAS-left main coronary trunk (LMT) ostial distance (20.3 ± 7.6 vs. 30.3 ± 8.4 mm; P = 0.005), with optimal cut-off values of ≤12.6 and ≤24.0 mm, respectively. A successful endo-EAS ablation was associated with an earlier electrogram at the endo-EAS [23 (8, 36) vs. 15 (0, 19) ms preceding the QRS; P < 0.001] and shorter epi-EAS-endo-EAS interval [6 (1, 8) vs. 22 (12, 25) ms; P < 0.001], with optimal cut-off values of ≥18 and ≤9 ms, respectively.

CONCLUSION

Shorter anatomical distances between the epi-EAS and ECS, and between the epi-EAS and LMT ostium, predict a successful ECS ablation. The prematurity of the endo-EAS electrogram and a shorter interval between the epi-EAS and endo-EAS predicted a successful endo-EAS ablation.

Для цитирования: Watanabe Ryuta, Nagashima Koichi, Shirai Yasuhiro, Kitai Takayuki, Okada Takuya, Tokuda Michifumi, Fukunaga Masato, Onuki Koumei, Nakatani Yosuke, Yoshimura Shingo, Takatsuki Seiji, Hashimoto Kenji, Yamashita Shuhei, Kato Masafumi, Uchida Fumiya, Fukamizu Seiji, Hojo Rintaro, Mori Hitoshi, Matsumoto Kazuhisa, Kato Hiroyuki, Suga Kazumasa, Sakurai Taku, Sakamoto Yusuke, Hayashi Tatsuya, Wakamatsu Yuji, Hirata Shu, Hirata Moyuru, Sawada Masanaru, Kurokawa Sayaka, Okumura Yasuo. Anatomical vs. electrophysiological approach for ablation of premature ventricular contractions originating from the left ventricular summit (ISESHIMA-SUMMIT Study).. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2024. DOI: 10.1093/europace/euae278.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.