MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2024.10.039

Медицинская библиотека · Heart rhythm · 2024

Multielectrode catheter-induced ectopy mapping: A novel technique for ablation of infrequent premature ventricular contractions.

Martins Raphaël P, Vlachos Konstantinos, Cortez-Dias Nuno, Groussin Pierre, Rakza Redwane, Behar Nathalie, Mabo Philippe, Leclercq Christophe, Pavin Dominique, Benali Karim

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Ablation of infrequent premature ventricular complexes (PVC) is challenging.

OBJECTIVES

A novel mapping strategy for patients with infrequent PVCs, called multielectrode catheter-induced ectopy mapping (MECIE mapping) is described, aiming at performing a hybrid activation/template matching map by taking advantage of multielectrode catheter-induced arrhythmogenicity.

METHODS

Patients referred to 3 tertiary centers for PVC ablation were prospectively enrolled if they had infrequent PVCs (less than 1 PVC per minute) at onset of procedure, preventing the realization of an accurate activation map. A detailed MECIE map was created using the arrhythmogenic property of multielectrode catheters, corresponding to a local activation time (LAT) map generated by annotating LAT from mechanical PVCs. Selecting mechanical PVCs with ≥99% concordance with the clinical PVC spotted the site of origin at which ablation was delivered. The primary endpoint was long-term success, defined as an >80% reduction in PVC burden during follow-up.

RESULTS

A total of 29 patients were included, with 25 (interquartile range [IQR] 7-30) PVCs in the initial 30 minutes of procedure. During MECIE mapping, 67 (IQR 1-332) points with ≥99% concordance were acquired. The best LAT was 34.0 ± 9.5 ms before QRS onset. Pace mapping was 97.4 ± 3.1% compared with the clinical PVC. Ablation was locally performed. After 13.2 ± 5.1 months of follow-up, 27 patients (93.1 %) had 80% reduction in PVC burden, and only 2 patients had symptomatic recurrences.

CONCLUSION

A detailed MECIE map taking advantage of multielectrode catheter arrhythmogenicity may be generated to spot the origin of PVCs, a strategy resulting in a good procedural success rate.

Для цитирования: Martins Raphaël P, Vlachos Konstantinos, Cortez-Dias Nuno, Groussin Pierre, Rakza Redwane, Behar Nathalie, Mabo Philippe, Leclercq Christophe, Pavin Dominique, Benali Karim. Multielectrode catheter-induced ectopy mapping: A novel technique for ablation of infrequent premature ventricular contractions.. Heart rhythm. 2024. DOI: 10.1016/j.hrthm.2024.10.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.