Accuracy of 11 intraocular lens calculation formulas in shallow anterior chamber eyes.

Yuan Haorui, Zhang Jiaqing, Han Xiaotong, Ye Jinfeng, Huang Yiguo, Huang Ruoxuan, Wen Ling, Qiu Xiaozhang, Chen Xiaoyun, Chen Kailin, Tan Xuhua, Luo Lixia

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the performance of intraocular lens (IOL) calculation formulas and the effect of anterior chamber depth (ACD), axial length (AL) and lens thickness (LT) on the prediction accuracy in shallow ACD eyes.

METHODS

This retrospective, consecutive case-series study included 648 eyes of 648 patients with an ACD < 3.0 mm who underwent phacoemulsification and IOL implantation. Eleven formulas were evaluated: Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) 2.0, Hill-Radial Basis Function (RBF) 3.0, Hoffer QST, Kane, Olsen, Pearl-DGS and traditional formulas (Haigis, Hoffer Q, Holladay 1 and SRK/T). Subgroup analysis was performed based on ACD, AL and LT.

RESULTS

Overall, the Hoffer QST and Kane showed no systematic bias. The Kane, EVO 2.0, Hill-RBF 3.0 and Hoffer QST had relatively lower mean absolute error and higher percentages of prediction error within ±0.5 D. For the ACD of 2.5-3.0 mm and AL < 22.0 mm subgroup, the Pearl-DGS exhibited the lowest MAE (0.45 D) and MedAE (0.41 D). Most formulas had a significant myopic bias (-0.43 to -0.18 D, p < 0.05) in the LT < 4.3 mm subgroup and a significant hyperopic bias (0.09-0.29 D, p < 0.05) in the LT ≥ 5.1 mm subgroup.

CONCLUSION

The Kane and Hoffer QST were recommended for shallow ACD eyes. In eyes with an ACD between 2.5 and 3.0 mm and a short AL, the Pearl-DGS showed excellent performance. Clinicians need to fine-tune the target refraction according to LT in shallow ACD eyes.

Для цитирования: Yuan Haorui, Zhang Jiaqing, Han Xiaotong, Ye Jinfeng, Huang Yiguo, Huang Ruoxuan, Wen Ling, Qiu Xiaozhang, Chen Xiaoyun, Chen Kailin, Tan Xuhua, Luo Lixia. Accuracy of 11 intraocular lens calculation formulas in shallow anterior chamber eyes.. Acta ophthalmologica. 2024. DOI: 10.1111/aos.16654.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.