Stopyra Wiktor, Cooke David L, Grzybowski Andrzej
Аннотация
PURPOSE: The proper selection of an intraocular lens power calculation formula is an essential aspect of cataract surgery. This study evaluated the accuracy of artificial intelligence-based formulas.
DESIGN: Systematic review.
METHODS: This review comprises articles evaluating the exactness of artificial intelligence-based formulas published from 2017 to July 2023. The papers were identified by a literature search of various databases (Pubmed/MEDLINE, Google Scholar, Crossref, Cochrane Library, Web of Science, and SciELO) using the terms "IOL formulas", "FullMonte", "Ladas", "Hill-RBF", "PEARL-DGS", "Kane", "Karmona", "Hoffer QST", and "Nallasamy". In total, 25 peer-reviewed articles in English with the maximum sample and the largest number of compared formulas were examined.
RESULTS: The scores of the mean absolute error and percentage of patients within ±0.5 D and ±1.0 D were used to estimate the exactness of the formulas. In most studies the Kane formula obtained the smallest mean absolute error and the highest percentage of patients within ±0.5 D and ±1.0 D. Second place was typically achieved by the PEARL DGS formula. The limitations of the studies were also discussed.
CONCLUSIONS: Kane seems to be the most accurate artificial intelligence-based formula. PEARL DGS also gives very good results. Hoffer QST, Karmona, and Nallasamy are the newest, and need further evaluation.
DESIGN: Systematic review.
METHODS: This review comprises articles evaluating the exactness of artificial intelligence-based formulas published from 2017 to July 2023. The papers were identified by a literature search of various databases (Pubmed/MEDLINE, Google Scholar, Crossref, Cochrane Library, Web of Science, and SciELO) using the terms "IOL formulas", "FullMonte", "Ladas", "Hill-RBF", "PEARL-DGS", "Kane", "Karmona", "Hoffer QST", and "Nallasamy". In total, 25 peer-reviewed articles in English with the maximum sample and the largest number of compared formulas were examined.
RESULTS: The scores of the mean absolute error and percentage of patients within ±0.5 D and ±1.0 D were used to estimate the exactness of the formulas. In most studies the Kane formula obtained the smallest mean absolute error and the highest percentage of patients within ±0.5 D and ±1.0 D. Second place was typically achieved by the PEARL DGS formula. The limitations of the studies were also discussed.