m+Medelevator.RU
← Поиск публикаций
Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2017

Outflow graft anastomosis site design could be correlated to aortic valve regurgitation under left ventricular assist device support.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Iizuka Kei, Nishinaka Tomohiro, Ichihara Yuki, Miyamoto Takuma, Yamazaki Kenji

Аннотация

Aortic valve regurgitation (AR) is a critical complication during circulatory support with a left ventricular assist device (LVAD). The time-course of AR and related factors, including outflow graft anastomosis site design, were investigated. Twenty-three patients who had continuous-flow LVAD implantation and were supported for more than 6 months were investigated. AR grade (none, 0; trivial, 0.5; mild, 1; mild-moderate, 1.5; moderate, 2; moderate-severe, 2.5; severe, 3) and aortic valve opening were evaluated with echocardiography. Computed tomography was performed to all the patients postoperatively. The angle of the outflow graft to the aorta (O-A angle, parallel 0; tangent 90°, 0-180°), aortic diameter at the anastomosis site, sino-tubular junction (STJ) diameter, distance between the STJ and the anastomosis site, and distance between the anastomosis site and the brachiocephalic artery were measured. The patients' age was 38 ± 11 years. Support duration was 686 ± 354 days. Mean AR grade after continuous-flow LVAD implantation was increased to around mild and was maintained thereafter. No patient needed any intervention to the aortic valve. The aortic valves of 82.6% of patients were closed continuously. The O-A angle (83 ± 14) was positively correlated with maximum AR grade (p = 0.0095). The O-A angle was significantly smaller in patients with maximum AR grade of 1 or less (77 ± 9°) than in those with 1.5 or greater (94 ± 15°, p = 0.021). The other CT measurements had no correlation with AR grade. In conclusion, the O-A angle was correlated with AR grade progression. The O-A angle appears to be one of the important factors related to AR under continuous-flow LVAD support.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты