The Journal of thoracic and cardiovascular surgery · 2017
Transapical transcatheter aortic valve replacement with a novel transcatheter aortic valve replacement system in high-risk patients with severe aortic valve diseases.
СтатьяVideo-Audio MediaНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zhu Liming, Guo Yingqiang, Wang Wei, Liu Huan, Yang Ye, Wei Lai, Wang Chunsheng
Аннотация
OBJECTIVES: The clinical experience of a novel transapical transcatheter aortic valve replacement system, the J-Valve (JC Medical Inc, Burlingame, Calif), in high-risk patients with severe aortic valve diseases is limited.
METHODS: A total of 107 high-risk patients (mean age, 74.4 ± 5.2 years) underwent transcatheter aortic valve replacement with the J-Valve from March 2014 to July 2015, which included 63 patients with aortic stenoses and 44 patients with aortic regurgitation. Echocardiography and contrast-enhanced computed tomography were used to evaluate patients' baseline characteristics and their follow-up conditions.
RESULTS: The J-Valve was successfully implanted in 102 patients (95.3%). Five patients (4.7%) underwent conversion to open surgery. The overall mortality was 4.7% (n = 5) at both 30 days and 6 months, whereas subgroup mortality was 6.3% (n = 4) in the aortic stenosis group and 2.3% (n = 1) in the aortic regurgitation group. Permanent pacemakers were implanted in 5 patients (4.7%). In the aortic stenosis group, paravalvular regurgitation was observed as none or trace in 54.2% of patients (n = 32), mild in 42.4% of patients (n = 25), and moderate in 3.4% of patients (n = 2) postprocedure. The mean aortic gradient decreased from 56.7 ± 15.2 mm Hg to 14.4 ± 7.8 mm Hg (P < .01). The peak aortic valve velocity declined from 4.76 ± 0.6 m/s to 2.45 ± 0.57 m/s (P < .01). In the patients with aortic regurgitation, paravalvular regurgitation was none or trace in 74.4% (n = 32), mild in 23.3% (n = 10), and 2.3% (n = 1) after the procedure. Mean aortic gradient was 7.1 ± 2.9 mm Hg.
CONCLUSIONS: Transcatheter aortic valve replacement by the J-Valve is an adequate clinical option to treat high-risk patients with severe aortic stenosis or aortic regurgitation.
METHODS: A total of 107 high-risk patients (mean age, 74.4 ± 5.2 years) underwent transcatheter aortic valve replacement with the J-Valve from March 2014 to July 2015, which included 63 patients with aortic stenoses and 44 patients with aortic regurgitation. Echocardiography and contrast-enhanced computed tomography were used to evaluate patients' baseline characteristics and their follow-up conditions.
RESULTS: The J-Valve was successfully implanted in 102 patients (95.3%). Five patients (4.7%) underwent conversion to open surgery. The overall mortality was 4.7% (n = 5) at both 30 days and 6 months, whereas subgroup mortality was 6.3% (n = 4) in the aortic stenosis group and 2.3% (n = 1) in the aortic regurgitation group. Permanent pacemakers were implanted in 5 patients (4.7%). In the aortic stenosis group, paravalvular regurgitation was observed as none or trace in 54.2% of patients (n = 32), mild in 42.4% of patients (n = 25), and moderate in 3.4% of patients (n = 2) postprocedure. The mean aortic gradient decreased from 56.7 ± 15.2 mm Hg to 14.4 ± 7.8 mm Hg (P < .01). The peak aortic valve velocity declined from 4.76 ± 0.6 m/s to 2.45 ± 0.57 m/s (P < .01). In the patients with aortic regurgitation, paravalvular regurgitation was none or trace in 74.4% (n = 32), mild in 23.3% (n = 10), and 2.3% (n = 1) after the procedure. Mean aortic gradient was 7.1 ± 2.9 mm Hg.
CONCLUSIONS: Transcatheter aortic valve replacement by the J-Valve is an adequate clinical option to treat high-risk patients with severe aortic stenosis or aortic regurgitation.
Предметные рубрики MeSH
AgedAortic ValveAortic Valve InsufficiencyAortic Valve StenosisConversion to Open SurgeryEchocardiography, Doppler, ColorEchocardiography, TransesophagealFemaleHeart Valve ProsthesisHumansMalePostoperative ComplicationsProsthesis DesignRecovery of FunctionRisk AssessmentRisk FactorsSeverity of Illness IndexTime FactorsTomography, X-Ray ComputedTranscatheter Aortic Valve ReplacementTreatment Outcome