EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2017
Omission of predilation in balloon-expandable transcatheter aortic valve implantation: retrospective analysis in a large-volume centre.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hamm Karsten, Reents Wilko, Zacher Michael, Halbfass Philipp, Kerber Sebastian, Diegeler Anno, Schieffer Bernhard, Barth Sebastian
Аннотация
AIMS: We aimed to evaluate the effect of omitting predilation on feasibility, procedural results and safety in balloon-expandable TAVI.
METHODS AND RESULTS: We performed an analysis of all 680 patients scheduled for a balloon-expandable TAVI prosthesis between January 2011 and August 2016. Patients treated with or without predilation were compared. Procedure times decreased from 85.6±42.9 to 56.7±26.1 minutes (p<0.001), fluoroscopy times from 9.5±5.7 to 6.2±3.9 minutes (p<0.001) and contrast volume from 131.9±60.8 to 85.4±37.4 ml (p<0.001) without predilation. Intraprocedural CPR was significantly more frequent in the predilation group (5.3% vs. 1.4%, p=0.01). Stroke rate was low at 1.5% and with no detectable difference. Applying VARC-2 definitions, the combined endpoints device success (88.3% vs. 92.4%, p=0.07) and clinical efficacy (88.7% vs. 92.4%, p=0.11) were comparable with or without prior valvuloplasty, while early safety was less frequent with predilation (85.2% vs. 90.2%, p=0.04). At 30 days, all-cause mortality and cardiovascular mortality were 6.8% with predilation vs. 2.9% without predilation (p=0.03) and 5.3% vs. 1.4% (p=0.01).
CONCLUSIONS: TAVI without prior valvuloplasty is feasible without apparent adverse impact in patients receiving a balloon-expandable TAVI prosthesis. The omission of predilation is associated with shorter procedure time, less radiation exposure and lower rates of intraprocedural resuscitation.
METHODS AND RESULTS: We performed an analysis of all 680 patients scheduled for a balloon-expandable TAVI prosthesis between January 2011 and August 2016. Patients treated with or without predilation were compared. Procedure times decreased from 85.6±42.9 to 56.7±26.1 minutes (p<0.001), fluoroscopy times from 9.5±5.7 to 6.2±3.9 minutes (p<0.001) and contrast volume from 131.9±60.8 to 85.4±37.4 ml (p<0.001) without predilation. Intraprocedural CPR was significantly more frequent in the predilation group (5.3% vs. 1.4%, p=0.01). Stroke rate was low at 1.5% and with no detectable difference. Applying VARC-2 definitions, the combined endpoints device success (88.3% vs. 92.4%, p=0.07) and clinical efficacy (88.7% vs. 92.4%, p=0.11) were comparable with or without prior valvuloplasty, while early safety was less frequent with predilation (85.2% vs. 90.2%, p=0.04). At 30 days, all-cause mortality and cardiovascular mortality were 6.8% with predilation vs. 2.9% without predilation (p=0.03) and 5.3% vs. 1.4% (p=0.01).
CONCLUSIONS: TAVI without prior valvuloplasty is feasible without apparent adverse impact in patients receiving a balloon-expandable TAVI prosthesis. The omission of predilation is associated with shorter procedure time, less radiation exposure and lower rates of intraprocedural resuscitation.
Предметные рубрики MeSH
AgedAged, 80 and overAortic ValveAortic Valve InsufficiencyAortic Valve StenosisBalloon ValvuloplastyFeasibility StudiesFemaleGermanyHeart Valve ProsthesisHospitals, High-VolumeHumansMaleOperative TimeProsthesis DesignRadiation DosageRadiation ExposureRetrospective StudiesRisk FactorsStrokeTime FactorsTranscatheter Aortic Valve ReplacementTreatment Outcome