MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/icvts/ivx023

Медицинская библиотека · Interactive cardiovascular and thoracic surgery · 2017

Precise moulded autologous pericardial configurations for aortic cusp reconstruction.

Izzat Mohammad Bashar, Hamzeh Khaled, Almohammad Farouk

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

In order to facilitate surgical repair of complex aortic cusp deformities and restoration of aortic valve competence, new moulds were developed to shape the glutaraldehyde-treated autologous pericardium into precise cusp-like configurations that can be used in aortic cusp reconstruction.

METHODS

The new moulds embodied the natural geometry of single aortic cusps, and a series of moulds were made available to correspond with all potential aortic cusp sizes. Aortic valve reconstruction using moulded autologous pericardial cusps was performed in 2 patients (both males, aged 14 and 19 years) with large outlet-type ventricular septal defects, extensive deformation of prolapsed right coronary cusps and severe aortic valve insufficiency. In each patient, the diseased right aortic cusp was excised and was replaced by a moulded autologous pericardial cusp that equalled the size of adjacent undiseased native cusps.

RESULTS

Excellent coaptation with adjoining native aortic cusps could be readily observed and intraoperative transoesophageal echocardiography confirmed satisfactory aortic valve repair (aortic insufficiency <1+ and low-transvalvular gradients). Follow-up transthoracic echocardiography confirmed that aortic valve function remained stable in both patients 2 years postoperatively.

CONCLUSIONS

Initial clinical experience indicated that constructing geometrically perfect cusp-like configurations was uncomplicated and implantation of the moulded autologous pericardial cusps restored adequate aortic valve competence. We believe that the simplicity and reproducibility of this approach may assist in the dissemination of aortic cusp reconstruction procedures.

Для цитирования: Izzat Mohammad Bashar, Hamzeh Khaled, Almohammad Farouk. Precise moulded autologous pericardial configurations for aortic cusp reconstruction.. Interactive cardiovascular and thoracic surgery. 2017. DOI: 10.1093/icvts/ivx023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.