EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2017
Transcatheter aortic valve replacement with the Portico valve: one-year results of the early Canadian experience.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Perlman Gidon Y, Cheung Anson, Dumont Eric, Stub Dion, Dvir Danny, Del Trigo Maria, Pelletier Marc, Alnasser Sami, Ye Jian, Wood David, Thompson Christopher, Blanke Philipp, Leipsic Jonathon, Seidman Michael A, LeBlanc Heather, Buller Christopher E, Rodés-Cabau Josep, Webb John G
Аннотация
AIMS: The aim of this study was to examine the short- and medium-term outcomes of transcatheter aortic valve replacement (TAVR) with the self-expanding and repositionable Portico valve (St. Jude Medical, St. Paul, MN, USA).
METHODS AND RESULTS: A total of 57 patients underwent TAVR with the Portico valve between March 2012 and August 2014, representing the first-in-human experience and the entire early experience in Canada. Patients were followed up at 30 days and one year with repeat echocardiography and clinical review. Patients were 80.8±7.3 years of age, and the Society of Thoracic Surgeons predicted risk of mortality was 7.7±5.7%. All patients had a valve implanted and four patients (7%) required a second valve. At 30 days, there were two deaths (3.5%), three disabling strokes (5.3%), and new pacemakers in five (8.8%) patients. Echocardiography revealed moderate/severe aortic regurgitation in two patients (3.6%). At one year, survival was 84.2% and echocardiographic findings were unchanged.
CONCLUSIONS: Transcatheter aortic valve replacement with the repositionable Portico valve provides satisfactory short- and medium-term haemodynamic and clinical results.
METHODS AND RESULTS: A total of 57 patients underwent TAVR with the Portico valve between March 2012 and August 2014, representing the first-in-human experience and the entire early experience in Canada. Patients were followed up at 30 days and one year with repeat echocardiography and clinical review. Patients were 80.8±7.3 years of age, and the Society of Thoracic Surgeons predicted risk of mortality was 7.7±5.7%. All patients had a valve implanted and four patients (7%) required a second valve. At 30 days, there were two deaths (3.5%), three disabling strokes (5.3%), and new pacemakers in five (8.8%) patients. Echocardiography revealed moderate/severe aortic regurgitation in two patients (3.6%). At one year, survival was 84.2% and echocardiographic findings were unchanged.
CONCLUSIONS: Transcatheter aortic valve replacement with the repositionable Portico valve provides satisfactory short- and medium-term haemodynamic and clinical results.