MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1535370219897617

Медицинская библиотека · Experimental biology and medicine (Maywood, N.J.) · 2020

In vivo evaluation of posterior eye elasticity using shaker-based optical coherence elastography.

Qian Xuejun, Li Runze, Li Yan, Lu Gengxi, He Youmin, Humayun Mark S, Chen Zhongping, Zhou Qifa

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

UNLABELLED: Age-related macular degeneration (AMD) is a progressive retinal disease and becomes the leading cause of blindness. It is well established that early detection is the key to preservation of functional vision. However, it is very difficult to diagnose AMD in very early stages, before structural changes are evident. Consequently, investigating the biomechanical properties of the retina maybe essential for understanding its physiological function. In this study, we present a shear wave-based quantitative method for estimating the elasticity of the posterior eye using shaker-based optical coherence elastography. This technique has been developed and validated on both a homogeneous phantom and a healthy rabbit in vivo. The shear wave speed from the ganglion side to the photoreceptor side of the rabbit eye is 4.1 m/s, 4.9 m/s, and 6.7 m/s, respectively. In addition, the most stiff sclera region has an average shear wave speed of 9.1 m/s. The results demonstrate the feasibility of using this technique to quantify biomechanical properties of the posterior eye and its potential translation to the clinical study.

IMPACT STATEMENT: Herein, we propose a potentially clinical applicable shaker-based optical coherence elastography (OCE) technique to characterize the biomechanical properties of the posterior eye, including different layers of the retina. Compared with either acoustic radiation force OCE or air-puff OCE, the newly developed method can induce sufficient shear wave propagation at the posterior eye with high resolution and large field of view.

Для цитирования: Qian Xuejun, Li Runze, Li Yan, Lu Gengxi, He Youmin, Humayun Mark S, Chen Zhongping, Zhou Qifa. In vivo evaluation of posterior eye elasticity using shaker-based optical coherence elastography.. Experimental biology and medicine (Maywood, N.J.). 2020. DOI: 10.1177/1535370219897617.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.