MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2022.07.005

Медицинская библиотека · JACC. Cardiovascular interventions · 2022

Impact of Right Ventricle-Pulmonary Artery Coupling on Clinical Outcomes in the PARTNER 3 Trial.

Cahill Thomas J, Pibarot Philippe, Yu Xiao, Babaliaros Vasilis, Blanke Philipp, Clavel Marie-Annick, Douglas Pamela S, Khalique Omar K, Leipsic Jonathon, Makkar Raj, Alu Maria C, Kodali Susheel, Mack Michael J, Leon Martin B, Hahn Rebecca T

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Physiologic right ventricle-pulmonary artery (RV-PA) coupling may be impaired in patients with aortic stenosis (AS).

OBJECTIVES

This study aimed to assess the incidence and prognostic significance of impaired RV-PA coupling in low-risk patients with symptomatic severe AS undergoing transcatheter aortic valve replacement or surgical aortic valve replacement.

METHODS

RV-PA coupling was measured by transthoracic echocardiography as the ratio of tricuspid annular plane systolic excursion (TAPSE) to pulmonary artery systolic pressure (PASP) in patients in the PARTNER (Placement of Aortic Transcatheter Valve) 3 trial. The primary endpoint was the composite of all-cause mortality, stroke, and rehospitalization at the 2-year follow-up.

RESULTS

Among 570 low-risk patients included in the analysis, RV-PA uncoupling was defined by a TAPSE/PASP ratio ≤ 0.55 mm/mm Hg. At baseline, 222 of 570 (38.9%) patients had RV-PA uncoupling. At 2 years, patients with baseline RV-PA uncoupling had an increased incidence of the primary endpoint (19.1% vs 9.9%, P = 0.002), all-cause mortality (5.9% vs 0.6%, P < 0.001), cardiovascular mortality (4.1% vs 0.6%, P = 0.003), and rehospitalization (13.5% vs 7.3%, P = 0.018). On multivariable analysis, baseline RV-PA uncoupling remained an independent predictor of the primary endpoint at 2 years (HR: 1.92; 95% CI: 1.04-3.57; P = 0.038).

CONCLUSIONS

In patients with symptomatic severe AS at low surgical risk undergoing transcatheter aortic valve replacement or surgical aortic valve replacement, baseline RV-PA uncoupling defined by TAPSE/PASP ≤ 0.55 mm Hg was associated with adverse clinical outcomes at 2 years, including all-cause mortality, cardiovascular mortality, and rehospitalization.

Для цитирования: Cahill Thomas J, Pibarot Philippe, Yu Xiao, Babaliaros Vasilis, Blanke Philipp, Clavel Marie-Annick, Douglas Pamela S, Khalique Omar K, Leipsic Jonathon, Makkar Raj, Alu Maria C, Kodali Susheel, Mack Michael J, Leon Martin B, Hahn Rebecca T. Impact of Right Ventricle-Pulmonary Artery Coupling on Clinical Outcomes in the PARTNER 3 Trial.. JACC. Cardiovascular interventions. 2022. DOI: 10.1016/j.jcin.2022.07.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.