m+Medelevator.RU
← Поиск публикаций
International journal of cardiology · 2022

Procedural outcomes of the 34 mm EvolutR Transcatheter valve in a real-world population insights from the HORSE multicenter collaborative registry.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gallo Francesco, Gallone Guglielmo, Kim Won-Keun, Reifart Jörg, Veulemans Verena, Zeus Tobias, Toggweiler Stefan, De Backer Ole, Søndergaard Lars, De Marco Federico, Regazzoli Damiano, Reimers Bernhard, Muntané-Carol Guillem, Estevez-Loureiro Rodrigo, Hernandez Ubaldo, Moscarelli Marco, Airale Lorenzo, D'Ascenzo Fabrizio, Armario Xavier, Mylotte Darren, Bhadra Oliver Daniel, Conradi Lenard, Donday Luis Alfonso Marroquin, Nombela-Franco Luis, Barbanti Marco, Reddavid Claudia, Criscione Enrico, Brugaletta Salvatore, Nicolini Elisa, Piva Tommaso, Tzanis Giorgos, Ronco Federico, Barbierato Marco, Rodes-Cabau Josep, Mangieri Antonio, Colombo Antonio, Giannini Francesco

Аннотация

OBJECTIVES: The aim of this study was to evaluate outcomes of real-world patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) with the 34 mm Evolut R (Medtronic, Minneapolis, Minnesota).

BACKGROUND: Larger aortic annulus has been associated with increased incidence of paravalvular leaks (PVLs) after TAVR. However, little is known, so far, about the performance of the 34 mm Evolut R in this setting.

METHODS: From the multicenter, international, retrospective Horizontal Aorta in Transcatheter Self-expanding Valves (HORSE) registry, including patients who underwent TAVR for native severe AS, we selected patients treated with the 34 mm Evolut R evaluating procedural characteristics and VARC-2 defined device success. We also compared 34 mm Evolut R with other Evolut R sizes.

RESULTS: Among the 4434 patients included in the registry, 572 (13%) received the 34 mm Evolut R valve. Mean age was 80.8 ± 6.5 years and the median STS PROM score was 4 [interquartile range 2-6]. Device success was achieved in 87.4% with 7.7% of PVLs; moreover, the rate of permanent pacemaker implantation (PPMI) was 22.4%. Patients who underwent 34 mm Evolut R implantation experienced more in-hospital permanent pacemaker implantation (22.4% vs. 15%; p < 0.001). At multivariate analysis, 34 mm Evolut R did not affect device success (OR: 0.81 [0.60-1.09]; p = 0.151). Device success was consistent with other THVs sizes (87.4% vs. 89.6%; p = 0.157).

CONCLUSIONS: THV replacement in patients requiring 34 mm Evolut R has an acceptable performance. Compared to other Medtronic sizes it demonstrated to be comparable in terms of device success, despite an increased rate of pacemaker implantation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты