MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2022.04.079

Медицинская библиотека · International journal of cardiology · 2022

Procedural outcomes of the 34 mm EvolutR Transcatheter valve in a real-world population insights from the HORSE multicenter collaborative registry.

Gallo Francesco, Gallone Guglielmo, Kim Won-Keun, Reifart Jörg, Veulemans Verena, Zeus Tobias, Toggweiler Stefan, De Backer Ole, Søndergaard Lars, De Marco Federico, Regazzoli Damiano, Reimers Bernhard, Muntané-Carol Guillem, Estevez-Loureiro Rodrigo, Hernandez Ubaldo, Moscarelli Marco, Airale Lorenzo, D'Ascenzo Fabrizio, Armario Xavier, Mylotte Darren, Bhadra Oliver Daniel, Conradi Lenard, Donday Luis Alfonso Marroquin, Nombela-Franco Luis, Barbanti Marco, Reddavid Claudia, Criscione Enrico, Brugaletta Salvatore, Nicolini Elisa, Piva Tommaso, Tzanis Giorgos, Ronco Federico, Barbierato Marco, Rodes-Cabau Josep, Mangieri Antonio, Colombo Antonio, Giannini Francesco

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to evaluate outcomes of real-world patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) with the 34 mm Evolut R (Medtronic, Minneapolis, Minnesota).

BACKGROUND

Larger aortic annulus has been associated with increased incidence of paravalvular leaks (PVLs) after TAVR. However, little is known, so far, about the performance of the 34 mm Evolut R in this setting.

METHODS

From the multicenter, international, retrospective Horizontal Aorta in Transcatheter Self-expanding Valves (HORSE) registry, including patients who underwent TAVR for native severe AS, we selected patients treated with the 34 mm Evolut R evaluating procedural characteristics and VARC-2 defined device success. We also compared 34 mm Evolut R with other Evolut R sizes.

RESULTS

Among the 4434 patients included in the registry, 572 (13%) received the 34 mm Evolut R valve. Mean age was 80.8 ± 6.5 years and the median STS PROM score was 4 [interquartile range 2-6]. Device success was achieved in 87.4% with 7.7% of PVLs; moreover, the rate of permanent pacemaker implantation (PPMI) was 22.4%. Patients who underwent 34 mm Evolut R implantation experienced more in-hospital permanent pacemaker implantation (22.4% vs. 15%; p < 0.001). At multivariate analysis, 34 mm Evolut R did not affect device success (OR: 0.81 [0.60-1.09]; p = 0.151). Device success was consistent with other THVs sizes (87.4% vs. 89.6%; p = 0.157).

CONCLUSIONS

THV replacement in patients requiring 34 mm Evolut R has an acceptable performance. Compared to other Medtronic sizes it demonstrated to be comparable in terms of device success, despite an increased rate of pacemaker implantation.

Для цитирования: Gallo Francesco, Gallone Guglielmo, Kim Won-Keun, Reifart Jörg, Veulemans Verena, Zeus Tobias, Toggweiler Stefan, De Backer Ole, Søndergaard Lars, De Marco Federico, Regazzoli Damiano, Reimers Bernhard, Muntané-Carol Guillem, Estevez-Loureiro Rodrigo, Hernandez Ubaldo, Moscarelli Marco, Airale Lorenzo, D'Ascenzo Fabrizio, Armario Xavier, Mylotte Darren, Bhadra Oliver Daniel, Conradi Lenard, Donday Luis Alfonso Marroquin, Nombela-Franco Luis, Barbanti Marco, Reddavid Claudia, Criscione Enrico, Brugaletta Salvatore, Nicolini Elisa, Piva Tommaso, Tzanis Giorgos, Ronco Federico, Barbierato Marco, Rodes-Cabau Josep, Mangieri Antonio, Colombo Antonio, Giannini Francesco. Procedural outcomes of the 34 mm EvolutR Transcatheter valve in a real-world population insights from the HORSE multicenter collaborative registry.. International journal of cardiology. 2022. DOI: 10.1016/j.ijcard.2022.04.079.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.