MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2021.10.027

Медицинская библиотека · JACC. Cardiovascular interventions · 2022

Propensity-Matched 1-Year Outcomes Following Transcatheter Aortic Valve Replacement in Low-Risk Bicuspid and Tricuspid Patients.

Deeb G Michael, Reardon Michael J, Ramlawi Basel, Yakubov Steven J, Chetcuti Stan J, Kleiman Neal S, Mangi Abeel A, Zahr Firas, Song Howard K, Gada Hemal, Mumtaz Mubashir, Heiser John, Merhi William, Murrah C Patrick, Noel Thomas, Kirshner Merick, Byrne Timothy, Ito Saki, Huang Jian, Forrest John K

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to compare 1-year outcomes after transcatheter aortic valve replacement (TAVR) in low surgical risk patients with bicuspid aortic stenosis to patients with tricuspid aortic stenosis.

BACKGROUND

The pivotal TAVR trials excluded patients with bicuspid aortic valves. The Low Risk Bicuspid Study 30-day primary endpoint of death or disabling stroke was 1.3%.

METHODS

The Low Risk Bicuspid Study is a prospective, single-arm, TAVR trial that enrolled patients from 25 U.S. sites. A screening committee confirmed bicuspid anatomy and valve classification on computed tomography using the Sievers classification. Valve sizing was by annular measurements. An independent clinical events committee adjudicated all serious adverse events, and an independent core laboratory assessed all echocardiograms. The 150 patients from the Low Risk Bicuspid Study were propensity matched to the TAVR patients in the randomized Evolut Low Risk Trial using the 1:1 5- to-1-digit greedy method, resulting in 145 pairs.

RESULTS

All-cause mortality or disabling stroke at 1 year was 1.4% in the bicuspid and 2.8% in the tricuspid group (P = 0.413). A pacemaker was implanted in 16.6% of bicuspid and 17.9% of tricuspid patients (P = 0.741). The effective orifice area was similar between groups at 1 year (2.2 ± 0.7 cm2 vs 2.3 ± 0.6 cm2, P = 0.677) as was the mean gradient (8.7 ± 3.9 mm Hg vs 8.5 ± 3.1 mm Hg, P = 0.754). Fewer patients in the bicuspid group had mild or worse paravalvular leak (21.3% vs 42.6%, P < 0.001).

CONCLUSIONS

There were no significant differences in clinical or forward flow hemodynamic outcomes between the propensity-matched groups at 1 year.

Для цитирования: Deeb G Michael, Reardon Michael J, Ramlawi Basel, Yakubov Steven J, Chetcuti Stan J, Kleiman Neal S, Mangi Abeel A, Zahr Firas, Song Howard K, Gada Hemal, Mumtaz Mubashir, Heiser John, Merhi William, Murrah C Patrick, Noel Thomas, Kirshner Merick, Byrne Timothy, Ito Saki, Huang Jian, Forrest John K. Propensity-Matched 1-Year Outcomes Following Transcatheter Aortic Valve Replacement in Low-Risk Bicuspid and Tricuspid Patients.. JACC. Cardiovascular interventions. 2022. DOI: 10.1016/j.jcin.2021.10.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.