m+Medelevator.RU
← Поиск публикаций
Gastrointestinal endoscopy · 2014

A newly designed fully covered metal stent for lumen apposition in EUS-guided drainage and access: a feasibility study (with videos).

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАVideo-Audio MediaНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Moon Jong Ho, Choi Hyun Jong, Kim Dong Choon, Lee Yun Nah, Kim Hee Kyung, Jeong Song Ah, Lee Tae Hoon, Cha Sang-Woo, Cho Young Deok, Park Sang Heum, Jeong Seok, Lee Don Haeng, Isayama Hiroyuki, Itoi Takao

Аннотация

BACKGROUND: A lumen-apposing stent can be used effectively under endosonographic guidance.

OBJECTIVE: To evaluate a newly designed, fully covered self-expandable metal stent with folding anchoring flanges for lumen apposition assembled on a conventional delivery system.

DESIGN: Retrospective case series and animal study.

SETTING: Tertiary care academic medical centers.

SUBJECTS: Six pigs for animal study and 7 patients, 3 of whom underwent endoscopic drainage for acute cholecystitis (AC) and 4 for pancreatic fluid collection (PFC).

INTERVENTION: Stent deployment under EUS guidance after puncturing, passage of an endoscope through the stent into the gallbladder (GB), or PFC with conventional endoscopic procedures.

MAIN OUTCOME MEASUREMENTS: Technical and clinical success, adverse events, and removability.

RESULTS: In the animal study, the stent was successfully inserted and deployed in the GB via a transgastric approach under EUS guidance without adverse events in all 6 pigs. Contrast injection demonstrated the absence of leakage. Cholecystoscopy with enhanced endoscopy was performed successfully in all animals after stent placement. All stents were intact and were removed successfully at 4 weeks. GB firmly adhered to the stomach with an intact cholecystogastric tract on necropsy and histopathology. The stents were successfully deployed without adverse effects in 7 patients. AC or PFC was resolved after stent placement in all patients. Endoscopic procedures were possible through the stent. Stent migration was not observed. The stent was successfully removed from the 4 patients with PFC after complete resolution.

LIMITATIONS: Small sample size, retrospective study.

CONCLUSIONS: Transenteric drainage and endoscopic intervention by using a novel fully covered self-expandable metal stent for lumen apposition under EUS guidance is feasible for the management of AC and PFC. Further study is warranted.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты