Simplified automated right ventricular overdrive pacing for rapid diagnosis of supraventricular tachycardia.
Оценочное исследованиеСтатьяВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Stec Sebastian, Sledź Janusz, Mazij Mariusz, Ludwik Bartosz, Labus Michał, Spikowski Jerzy, Szydłowski Lesław, Klank-Szafran Monika, Kraszewska Ewa, Budzikowski Adam S
Аннотация
OBJECTIVES: The purpose of this study was to prospectively evaluate the feasibility and diagnostic value of right ventricular overdrive pacing (RVOP) during supraventricular tachycardia (SVT) using a 2-catheter approach with automatic pacing from the right ventricular inflow (RVIT) and outflow tract (RVOT).
METHODS: One hundred and thirty-six consecutive patients (with 138 arrhythmias, mean age 36 ± 20 years, range 4-95) were enrolled in this study. Only coronary sinus and ablation catheters were used. RVOP was delivered from RVIT and then from RVOT. Each attempt consisted of 10 synchronized beats delivered at a cycle length of 10-40 ms longer than the tachycardia cycle length.
RESULTS: RVOP was sufficient to confirm the transition zone within the first 9 beats in the majority of SVTs. Atrial perturbation (acceleration, delayed) in the transition zone was detected in all patients with orthodromic atrioventricular (AV) reentry. Patients with typical AV nodal reentry, atypical AV nodal reentry and atrial tachycardia did not show atrial timing perturbation during fusion complexes of RVOP.
CONCLUSIONS: Synchronized RVOP from RVIT or RVOT is an easy and accurate method for the quick and reliable differential diagnosis of SVT in various clinical settings, particularly when only a limited number of catheters are used.
METHODS: One hundred and thirty-six consecutive patients (with 138 arrhythmias, mean age 36 ± 20 years, range 4-95) were enrolled in this study. Only coronary sinus and ablation catheters were used. RVOP was delivered from RVIT and then from RVOT. Each attempt consisted of 10 synchronized beats delivered at a cycle length of 10-40 ms longer than the tachycardia cycle length.
RESULTS: RVOP was sufficient to confirm the transition zone within the first 9 beats in the majority of SVTs. Atrial perturbation (acceleration, delayed) in the transition zone was detected in all patients with orthodromic atrioventricular (AV) reentry. Patients with typical AV nodal reentry, atypical AV nodal reentry and atrial tachycardia did not show atrial timing perturbation during fusion complexes of RVOP.
CONCLUSIONS: Synchronized RVOP from RVIT or RVOT is an easy and accurate method for the quick and reliable differential diagnosis of SVT in various clinical settings, particularly when only a limited number of catheters are used.